2009-01-29 08:17:09 | 2004 FBC W/2007 REVISIONS | | RE-ROOF TILE TO TILE | | | | DENIED BY BUILDING | | | | 1) PER DCA RULE 9B-3.0475 HURRICANE MITIGATION | | RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY | | RESIDENTIAL STRUCTURES, THE VALUE OF THE BUILDING FOR | | AD VALOREM TAXATION IS MORE THAN $300,000.00. | | THEREFORE, THE REQUIREMENTS OF SECTION 101.2 FOR ROOF | | TO WALL CONNECTIONS MUST BE ADDRESSED. SUBMIT THE | | APPROPRIATE DOCUMENTATION TO SHOW COMPLIANCE. | | | | 2) THE PRODUCT APPROVAL SUBMITTED FOR THE HANSON ROOF | | TILE IS AN ICC LEGACY REPORT WHICH REQUIRES THE | | APPROPRIATE NATIONAL EVALUATION SERVICES, INC. OR SBCCI | | PST & ESI EVALUATION REPORT FOR THE POLYFOAM ADHESIVE | | FASTENING SYSTEM. THESE REPORTS SPECIFY THE UPLIFT | | MOMENTS FOR THE TILE. THE MIAMI-DADE NOA THAT WAS | | SUBMITTED FOR THE POLYFOAM DOES NOT SPECIFY THE UPLIFT | | MOMENT BECAUSE IT IS SPECIFIED IN THE TILE NOA. SUBMIT | | PRODUCT APPROVALS FOR TILE AND ADHESIVES THAT | | CORRESPOND WITH EACH OTHER. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|