2009-04-06 14:55:27BUILDING REVIEW APPROVED WITH PROVISO:
  
 1- RE-SUBMIT PRODUCT APPROVAL FOR ROOF TILE ADHESIVE.
 NEED TO PROVIDE REPORT # 9822B AS SHOWN ON FLORIDA
 PRODUCT APPROVAL FL830-R1. ESR-1709 REPORT SUBMITTED
 DOESN'T CORRESPOND TO FL830-R1.
  
 2- PROVIDE DIMENSIONS ON DETAIL 3/S-1 TO SHOW
 COMPLIANCE WITH RISER/TREAD RATIO SEC. R311.5.3.2 OF
 2004 FLORIDA RESIDENTIAL CODE.
  
 3- SPECIFY MIN. 8D RING SHANK NAILS ON DETAIL D-1/A-2
 SIDE VIEW DETAIL. ALSO, REVISE ROOF SHEATHING FASTENING
 SPECIFICATIONS ON DETAIL 5/S-2 TO COMPLY WITH SEC.
 R803.2.3.1 OF 2004 FLORIDA RESIDENTIAL CODE.