Notes
Date Text
2009-02-17 16:50:15RESIDENTIAL (R3) ALTERATION, BUILDING REVIEW CHECKLIST.
 REVIEW UNDER 2004 FLORIDA RESIDENTIAL CODE WITH 2007
 REVISIONS.
  
 1- SHEET SP-1:
 A) DESIGN CRITERIA SPECIFIES BUILDING TO BE ON EXPOSURE
 "C", WHILE DESIGN CRITERIA ON SHEET S-1 AND SHEET S-2
 SPECIFIES EXPOSURE "B". REVISE AS REQUIRED TO MATCH.
 AND, PROVIDE CORRESPONDING DESIGN PRESSURES.
  
 B) CLARIFY IF CONSTRUCTION TYPE IS VA OR VB.
  
 2- SPECIFY TYPE OF EXISTING LOUVERS AND PROVIDE DETAILS
 SHOWING HOW ARE THEY GOING TO BE RE-INSTALLED
 CONSIDERING THAT NEW WINDOWS WILL BE INSTALLED ON SAME
 OPENING TO VERIFY COMPLIANCE WITH THE DESIGN LOADS OF
 SEC. R301 OF 2004 FLORIDA RESIDENTIAL CODE.
  
 3- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9B-72 FOR:
 A) WINDOW MULLIONS. AND, CLEARLY MARK SPECIFIC MULLION
 SIZE AND ANCHORING TO VERIFY COMPLIANCE WITH THE
 CALCULATED DESIGN PRESSURES.
  
 B) ROOF TILE ADHESIVE TO BE USED. SEE PRODUCT APPROVAL
 FOR REFERENCED INFORMATION.
  
 4- DESIGNER OF RECORD TO REVIEW AND APPROVE ALL PRODUCT
 APPROVALS PRIOR TO SUBMITTAL TO THIS OFFICE. SEC.
 106.3.3 CITY AMENDMENTS TO FBC 2004.
  
 5- REVISE DETAIL 3/S-1 TO COMPLY WITH THE RISER/TREAD
 RATIO OF SEC. R311.5.3.2 OF 2004 FLORIDA RESIDENTIAL
 CODE.
  
 6- PROVIDE SPECIFICATION FOR TONGUE AND GROOVE ROOF
 SHEATHING FOR NEW CANOPY. SEC. R803.2.3.1 OF 2004
 FLORIDA RESIDENTIAL CODE.
  
 7- EXTERIOR ELEVATIONS CARDINAL ORIENTATION SHOWN ON
 SHEET D-2 DON'T CORRESPOND TO ORIENTATION SHOWN ON
 SHEET A-3. EG: FRONT ELEVATION IS CALLED NORTH ON SHEET
 D-2, BUT CALLED SOUTH ON SHEET A-3. REVISE ALL AS
 REQUIRED.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved