2009-04-08 16:49:06RESIDENTIAL (R3) ADDITION, BUILDING REVIEW SECOND
 CHECKLIST.
 REVIEW UNDER 2004 FLORIDA RESIDENTIAL CODE WITH 2007
 REVISIONS.
  
 1- NEED RECORDED NOTICE OF COMMENCEMENT AS REQUIRED BY
 SEC. 713.13 FLORIDA STATUTE.
 ***NOTE: THIS MAY BE RECORDED AT TIME OF PERMIT PICK
 UP.
  
 2- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH
 COUNTY (2300 N. JOG RD (561)233-5120) TO CHECK IF
 IMPACT FEES ARE DUE. BRING BACK STAMPED PLANS AND COPY
 OF PAID RECEIPT. (REPEAT COMMENT. NOT ADDRESSED AT
 ALL).
  
 3- DIMENSIONS SHOWN ON FLOOR PLANS ARE NOT LEGIBLE.
 THEY ARE EXTREMELY LIGHT TO READ. REVISE AS REQUIRED.
 SEC. 106.1.3 CITY AMENDMENTS TO FBC 2004.
  
 4- SPECIFY CURRENT CODE 2004 FLORIDA RESIDENTIAL CODE
 WITH 2007 REVISIONS. CODE TABULATION INFORMATION ON
 SHEET A-1 IS REFERRING TO 2007 FBC. THIS PERMIT
 APPLICATION WAS SUBMITTED UNDER THE 2004 FLORIDA
 RESIDENTIAL CODE WITH 2007 REVISIONS. REVISE AS
 REQUIRED.
  
 5- PROVIDE COMPLETE GABLE END DETAIL THAT SHOWS
 COMPLIANCE WITH SEC. R609.4 OF 2004 FLORIDA RESIDENTIAL
 CODE. (REPEAT COMMENT). DETAIL SHOWN ON SHEET A-3 IS
 FOR WOOD FRAMED WALL. NEED DETAIL FOR MASONRY
 CONSTRUCTION AS SHOWN ON FLOOR PLANS. PROVIDE COMPLETE
 SPECIFICATIONS FOR SIZE AND FASTENING OF BOTTOM SILL
 PLATE, GABLE END FASTENING TO THE BOTTOM SILL AND GABLE
 END OUTLOOKERS (ROOF RAFTERS) TO GABLE END TRUSS TO
 SHOW COMPLIANCE WITH SEC. R601.2 OF 2004 FLORIDA
 RESIDENTIAL CODE.
  
 6- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC.
 13-600 OF 2004 FBC.
 A) PLEASE MAKE SURE CORRECT 2004 REVISED FORM IS USED.
 (REPEAT COMMENT). FORM SUBMITTED WAS FORM 600A-2001.
 THIS FORM IS NOT ONLY THE OLD CODE, BUT IS NOT THE
 REVISED FORM EITHER. NEED TO USE FORM 600A-2004R.
  
 B) OVERHANG HEIGHT SHOWN ON PAGE TWO IS INCORRECT. SEE
 SEC. 13-601.2.A.3 AND FIGURE 6.1 OF 2004 FBC TO SEE HOW
 THE DIMENSIONS FOR THE OVERHANG HEIGHT AND LENGTH ARE
 TAKEN AND REVISE AS REQUIRED.
  
 C) OWNER/AGENT TO SIGN AND DATE BOTTOM OF FORM. (REPEAT
 COMMENT).
  
 D) COMPLETE ALL INFORMATION ON TOP OF FORM.
  
 7- PROVIDE 2 COPIES OF PRODUCT APPROVALS AS REQUIRED BY
 DCA RULE 9B-72 FOR:
 A) ROOF SHINGLES. (REPEAT COMMENT. NOT ADDRESSED AT
 ALL).
  
 B) HURRICANE SHUTTERS. AND, PROVIDE COMPLETE
 INSTALLATION SCHEDULE. SEE ATTACHED COPY. ALSO, CLEARLY
 MARK ON SHUTTERS DRAWINGS SPECIFIC MOUNTING CONDITIONS
 (EG: WALL MOUNTED, BUILD OUT, ETC.) AND SPECIFIC ANCHOR
 TYPE AND SPACING TO BE USED. (REPEAT COMMENT. NOT
 ADDRESSED AT ALL).
 ***NOTE: ENGINEER'S WINDOW SCHEDULE ON SHEET A-1
 SPECIFIES IMPACT GLASS, WHILE PRODUCT APPROVAL
 SUBMITTED IS FOR NON-IMPACT GLASS. COORDINATE
 INFORMATION AS REQUIRED TO MATCH.
  
 8- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004.
 (REPEAT COMMENT. NOT ADDRESSED AT ALL).
  
 9- MIN. THICKNESS OF STUCCO ON FRAME CONSTRUCTION IS
 7/8" AS REQUIRED BY SEC. R703.6.4.3 OF 2004 FLORIDA
 RESIDENTIAL CODE ( ASTM C926 AND ASTM C-1063). (REPEAT
 COMMENT). EXTERIOR ELEVATIONS ON SHEET A-1 AND BUILDING
 SECTION ON SHEET A-2 SPECIFY 5/8" STUCCO THICKNESS.
 REVISE AS REQUIRED.
  
 10- SPECIFY/CLARIFY HOW COMPLYING WITH THE EGRESS
 REQUIREMENTS OF SEC. R310 OF 2004 FLORIDA RESIDENTIAL
 CODE IF THE EXISTING WINDOW CAN'T BE USED BECAUSE OF
 BATHROOM ADDITION. (REPEAT COMMENT. NOT ADDRESSED AT
 ALL).
  
 11- SPECIFY SAFETY GLASS FOR WINDOW BY TUB AREA AS
 REQUIRED BY SEC. R308.4 OF 2004 FLORIDA RESIDENTIAL
 CODE. (REPEAT COMMENT). WINDOW SCHEDULE CALLS FOR
 IMPACT GLASS, BUT PRODUCT APPROVAL SUBMITTED IS FOR
 NON-IMPACT GLASS. COORDINATE INFORMATION AS REQUIRED TO
 MATCH.
  
 12- RETURN REVIEWED SET AFTER CORRECTIONS ARE DONE TO
 ORIGINAL DRAWINGS TO EXPEDITE REVIEW PROCESS.
  
 13- SURVEY CAN'T BE COPIED BECAUSE OF COPYRIGHT ISSUES.
 REMOVE SURVEY INFORMATION ON SHEET A-1. DRAWINGS TO
 SHOW SITE PLAN, NOT COPY OF SURVEY. BESIDES THIS SURVEY
 CAN'T BE USED FOR CONSTRUCTION. SEE NOTE #5 ON SURVEY.
 (REPEAT COMMENT. NOT ADDRESSED AT ALL).
  
 14- CLARIFY WHY KNEE WALL SHOWS ONLY ONE TOP PLATE IF
 THIS IS A BEARING WALL?. SEE CHAPTER 6 OF 2004 FLORIDA
 RESIDENTIAL CODE. (REPEAT COMMENT). PLANS SUBMITTED NOW
 SPECIFY ROOF TRUSS, BUT DRAWING STILL SHOWS KNEE WALL.
 REVISE AS REQUIRED.
  
 15- SPECIFY R-VALUES ON CEILING AND WALLS. COORDINATE
 WITH THE ENERGY CALCULATIONS. (REPEAT COMMENT). MISSING
 INFORMATION FOR WALLS.
  
 16- SPECIFY HOW LONG ARE THE BOLTS SPECIFIED TO HOLD
 THE 2X8 WOOD PLATE SHOWN ON BUILDING SECTION A/2.
 (REPEAT COMMENT. NOT ADDRESSED AT ALL).
  
 17- SPECIFY ROOF VENTILATION TO COMPLY WITH SEC. R806
 OF 2004 FLORIDA RESIDENTIAL CODE. PLANS AND SECTIONS
 SUBMITTED DON'T PROVIDE ANY INFORMATION.
  
 18- SPECIFY FIREBLOCKING MATERIAL AND LOCATION IN WALL
 SECTION TO VERIFY COMPLIANCE WITH SEC. R602.1.2 OF 2004
 FLORIDA RESIDENTIAL CODE. BUILDING SECTION DOESN'T
 PROVIDE ANY INFORMATION.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712