2009-03-31 10:31:06BUILDING PLAN REVIEW
 PERMIT: 08120369
 ADD: 100 N CLEMATIS ST
 CONT: CATALFUMO
 TEL: (561)282-8265
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 APRIL 1/ 2009
  
 ARCHITECT: STEPHEN BORUFF
 STEPHEN L. BORUFF, AIA
 ARCHITECTS+ PLANNERS, INC.
  
 STRUCTURAL ENGINEER: TOLLIVER J. FRAZIER
 ONM&J STRUCTURAL ENGINEERS
  
  
 BUILDING PROVISO:
  
  
 1) ROOFING SYSTEMS:
 ROOF INSULATION REVIEW THE MINIMUM THICKNESS FOR A 20.4
 R-VALUE SEE ENERGY INPUT DATA REPORT
 PRODUCT APPROVAL NOA 07-0228.04
 DECK TYPE 21: STEEL INSULATED
 DECK DESCRIPTION 18-22 GAUGE TYPE B
 SYSTEM TYPE B(1)
 MAXIMUM DESIGN PRESSURE -75 PSF LIMITATION # 7 ALLOWS
 FOR ENHANCED FASTENING S-4 FOR THE ROOF ZONE 3 REQUIRES
 -107.
 THE RAS 117 CALCULATIONS CAN BE COMPLETED BY EITHER A
 ARCHITECT, ENGINEER OR REGISTEERED ROOF CONSULTANT.
  
 ARCHITECT RESPONSE: ROOFING SHOP DRAWING/ PRODUCT
 SUBMITTAL SHALL INCLUDE FASTENER CALCULATIONS.
 FASTENER CALCULATIONS ARE TO BE SUBMITTED AS PART OF
 THE ROOFING PERMIT UNDER SEPERATE REVIEW.
  
 2) FBC BUILDING 3110.1.2 / CITY OF WPB CODE OF
 ORDINANCES SECTION 94-546. STRUCTURE IS LOCATED IN AN
 "A" FLOOD ZONE. A FLOOD ELEVATION CERTIFICATE WILL BE
 REQUIRED BEFORE A CERTIFICATE OF OCCUPANCY WILL BE
 ISSUED.
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved