Plan Review Notes
Plan Review Notes For Permit 08120340
Permit Number 08120340
Review Stop P
Sequence Number 1
Notes
Date Text
2009-01-28 13:40:39DENIED
 REFERENCE:
 FBC-2004 PLUMBING
 FBC-2004 BUILDING
 FBC-2004 CHAPTER 1
 FBC-2004 CHAPTER 11
  
 1. SHT A-1 SHOW COMPLIANCE WITH THE FOLLOWING:
 ___LAV:
 A. 11-4.19.2 CLEARANCE (29" REQD)
 B. 11-4.19.4 EXPOSED PIPES & SURFACES
 C. 11-4.19.5 FAUCETS
  
 2. SHT A-1 SHOW THE WATER CLOSET 1'6" OFF THE WALL TO
 THE CENTERLINE OF THE FIXTURE. CHAPTER 11 FIGURE 28. --
 SHOW THE LAV MINIMUM 15" OFF THE WALL TO THE CENTERLINE
 OF THE FIXTURE. (FIXTURE SHALL BE CENTERED ON THE 30"
 MEASUREMENT OF THE 30"X48" CLEAR FLOOR SPACE).
  
 3. SHT A-1 TOILET ROOM. PLEASE INDICATE THE LENGTH AND
 WIDTH DIMENSIONS OF THE TOILET ROOM AND INDICATE
 COMPLIANCE WITH THE FINISH REQUIREMENTS PER SECTIONS
 1210.1 & 1210.2. FLOOR REQUIREMENTS & WALLS WITHIN 2
 FEET OF THE WATER CLOSET SHALL HAVE A SMOOTH, HARD,
 NONABSORBENT SURFACE. SECTION 106.1.2.
  
 4. SHT MEP-1 PLUMBING NOTES, CODE CRITERIA INDICATES
 COMPLIANCE WITH THE STANDARD PLUMBING CODE. THE CODE
 ADOPTED IS THE FBC-2004 PLUMBING CODE WITH 2007
 AMENDMENTS. PLEASE INDICATE ON PLANS. SECTION 106.1.1.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  