2009-01-05 14:18:00 | BUILDING PLAN REVIEW |
| PERMIT: 08120340 |
| ADD: 410 EVERNIA ST # 115 |
| CONT: R. W. MARRELL |
| TEL: (321)609-1686 |
| |
| FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| W/ 2007 FBC REVISIONS |
| * WEST PALM BEACH AMENDMENTS |
| |
| 1ST REVIEW |
| ACTION: DENIED |
| |
| 1A) INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE |
| INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS |
| NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| COOPERATION. |
| |
| 1B) INFORMATIONAL FL S S 713.13 NOTICE OF COMMENCEMENT, |
| TO BE FILED WITH THE CLERK OF THE COURT. NOTE: |
| 713.13(2) IF THE WORK DESCRIBED IN THE NOTICE OF |
| COMMENCEMENT IS NOT ACTUALLY COMMENCED WITHIN 90 DAYS |
| AFTER THE RECORDING THEREOF, SUCH NOTICE IS NULL & |
| VOID. NOTE: 713.13(6) THE POSTING OF THE NOTICE OF |
| COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST |
| INSPECTION. |
| |
| 1C) INFORMATIONAL: PLANS SUBMITTED FOR PERMIT (FIRST |
| TIME REVIEW) AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO |
| THE 2004 FBC BUILDING WITH THE 2007 SUPPLEMENTS AND |
| 2004 EXISTING BUILDING CODE. |
| PLEASE PROVIDEE TO WHAT LEVEL ALTERATION THIS PROJECT |
| WILL BE? EXISTING BUILDING CODE 301.5 THE DESSIGNER OF |
| RECORD OR AN OWNER MUST ELECT THE LEVEL OF ALTERATION |
| PURSUANT TO SECTION 303,304 AND 305 OF THIS CODE. |
| |
| 2) 110.2* W. P. B. ADMINISTRATIVE CODE, INFORMATION |
| THAT IS REQUIRED FOR RECORD KEEPING & FOR CERTIFICATE |
| OF OCCUPANCY: |
| A) THE EDITION OFTHE CODE UNDER WHICH THE PROJECT IS |
| DESIGNED. |
| B) THE USE AND OCCUPANCY, IN ACCORDANCE WITH THE |
| PROVISIONS OF CHAPTER 3. |
| C) THE TYPE OF CONSTRUCTION AS DEFINED IN CHAPTER 6, |
| TABLE 601. |
| D) THE OCCUPANT LOAD, SEE 1004. |
| E) IF AN AUTOMATIC SPRINKLER SYSTEM IS PROVIDED |
| F) WHETHER THE SPRINKLER SYSTEM IS REQUIRED. |
| G) ANY SPECIAL STIPULATIONS & CONDITIONS OF THE |
| BUILDING PERMIT |
| H )NUMBER OF FLOORS WITHIN THE BUILDING |
| |
| 3) THE LIVE/ WORK LOFT, IS THIS A MEZANINE AS INDICATED |
| IN THE FIRE SPRINKLER PLAN. SEE AATTACHMENT OF HOW TO |
| CALCULATE THE ALLOWABLE FLOOR AREA WHEN WALLS ARE ADDED |
| BENEATH THE MEZZANINE LEVEL. SECTION 505.2.AREA OF |
| MEZZANINE . THE AGGREGATE AREA OF A MEZZANINE OR |
| MEZZANINES WITHIN A ROOM SHALL NOT EXCEED ONE-THIRD OF |
| THE AREA OF THAT ROOM OR SPACE IN WHICH THEY ARE |
| LOCATED. THE ENCLOSED PORTIONS OF ROOMS SHALL NOT BE |
| INCLUDED IN A DETERMINATION OF THE SIZE OF THE ROOM IN |
| WHICH THE MEZZANINE IS LOCATED. IN DETERMINING THE |
| ALLOWABLE MEZZANINE AREA, THE AREA OF THE MEZZANINE |
| SHALL NOT BE INCLUDED IN THE AREA OF THE ROOM. WITH THE |
| ADDITIONAL WALLS BELOW THE MEZANINE THE ALLOWABLE SPACE |
| IS DECREASED FOR THE MEZZANINE LEVEL. |
| |
| |
| A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A |
| RESULT OF THE ADDITIONAL INFORMATION REQUESTED |
| ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF |
| THIS REVIEW. |
| |
| JIM WITMER C. B. O. |
| BUILDING PLAN REVIEW II |
| |
| TEL: (561)805-6715 |
| FAX: (561)805-6731 |
| E-MAIL: [email protected] |
| |
| PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| |
| |
| |