2009-03-04 16:16:52 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBC FLORIDA BUILDING CODE 2004 | | FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | FAC FLORIDA ADMINISTRATIVE CODE | | FS FLORIDA STATUTE | | | | 1-10. ADDRESSED. | | | | 11. SPECIFY ROOF DESIGN PRESSURE, FBC R301. | | | | 2ND REVIEW, NOT ADDRESSED. SEE FBC1609. PLEASE SPECIFY | | PRESSURES AS REQUESTED. | | | | 3RD REVIEW, NOT ADDRESSED. | | | | NEW COMMENTS: | | | | PLEASE CHECK ALL INFORMATION ON A1. LEVEL 1 ALTERATION | | DECLARED; THIS IS AN ADDITION, HOW CAN THIS BE A LEVEL | | I? BUILDING TYPE III V DECLARED; PLEASE GIVE CODE | | SECTION WHERE III V IS A BUILDING TYPE. .18 PRESSURE | | COEFFICIENT STATED; THIS IS A PORCH OPEN ON TWO SIDES. | | SHOULDN'T YOU BE DESIGNING TO A PARTIALLY ENCLOSED | | CONDITION? HOW HAVE "ACTUAL LOADS' ON THE TRUSS | | ANCHORAGE SCHEDULE BEEN DETERMINED? | | | | SHUTTER PRODUCT APPRPOVALS SUBMITTED; WHY ARE THEY IN | | THIS PACKAGE? PLEASE REMOVE; IT APPEARS THEY BELONG TO | | A DIFFERENT PERMIT. | | | | A SET HAS BEEN RETAINED. WHEN RESUBMITTING, PROVIDE TWO | | COMPLETE ORIGINAL SETS. | | |
|