Plan Review Notes
Plan Review Notes For Permit 08120189
Permit Number 08120189
Review Stop B
Sequence Number 1
Notes
Date Text
2009-01-16 11:44:402004 FBC W/2007 REVISIONS
 NEW TOWNHOUSE
  
 DENIED BY BUILDING
  
 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT WILL
 BE REQUIRED. FS 713
  
 2) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED. (561) 233-5025
  
 3) THE STRUCTURE IS LOCATED IN AN "AO" FLOOD ZONE. AN
 ELEVATION CERTIFICATE WILL BE REQUIRED.
  
 4) R401.4 SOIL TESTS.
 IN AREAS LIKELY TO HAVE EXPANSIVE, COMPRESSIBLE,
 SHIFTING OR OTHER UNKNOWN SOIL CHARACTERISTICS, THE
 BUILDING OFFICIAL SHALL DETERMINE WHETHER TO REQUIRE A
 SOIL TEST TO DETERMINE THE SOIL?S CHARACTERISTICS AT A
 PARTICULAR LOCATION. THIS TEST SHALL BE MADE BY AN
 APPROVED AGENCY USING AN APPROVED METHOD. SUBMIT A
 GEOTECHNICAL REPORT
 TO VERIFY THE SAFE BEARING CAPACITY OF
 THE SOIL.
  
 5) FAC 61G-16.004(6) REQUIRES THE PRINTED NAME OF THE
 PERSON SEALING THE DOCUMENT TO APPEAR IN THE TITLE
 BLOCK ON EACH SHEET.
  
 6) SUBMIT SIGNED AND SEALED TRUSS DRAWINGS THAT HAVE
 BEEN REVIEWED AND APPROVED BY THE DESIGNER OF RECORD
 FOR THE STRUCTURE. R502.1.3.4
  
 7) SOME OF THE STRUCTURES IN THE PROJECT WILL BE
 LOCATED IN EXPOSURE CATEGORY C, WHICH REQUIRES HIGHER
 DESIGN PRESSURES THAN EXPOSURE B. IN ORDER FOR THE
 PLANS TO BE MASTERED, THE STRUCTURES WILL NEED TO BE
 DESIGNED EXPOSURE C, WHICH IS WORST CASE. SEE FBC
 R301.2.1.4 R301.2.1.4 EXPOSURE CATEGORY.
 FOR EACH WIND DIRECTION CONSIDERED, AN EXPOSURE
 CATEGORY THAT ADEQUATELY REFLECTS THE CHARACTERISTICS
 OF GROUND SURFACE IRREGULARITIES SHALL BE DETERMINED
 FOR THE SITE AT WHICH THE BUILDING OR STRUCTURE IS TO
 BE CONSTRUCTED. FOR A SITE LOCATED IN THE TRANSITION
 ZONE BETWEEN CATEGORIES, THE CATEGORY RESULTING IN THE
 LARGEST WIND FORCES SHALL APPLY. ACCOUNT SHALL BE TAKEN
 OF VARIATIONS IN GROUND SURFACE ROUGHNESS THAT ARISE
 FROM NATURAL TOPOGRAPHY AND VEGETATION AS WELL AS FROM
 CONSTRUCTED FEATURES. FOR ANY GIVEN WIND DIRECTION, THE
 EXPOSURE IN WHICH A SPECIFIC BUILDING OR OTHER
 STRUCTURE IS SITED SHALL BE ASSESSED AS BEING ONE OF
 THE FOLLOWING CATEGORIES: 3. EXPOSURE C. OPEN TERRAIN
 WITH SCATTERED OBSTRUCTIONS, INCLUDING SURFACE
 UNDULATIONS OR OTHER IRREGULARITIES, HAVING HEIGHTS
 GENERALLY LESS THAN 30 FEET (9144 MM) EXTENDING MORE
 THAN 1,500 FEET (457.2 M) FROM THE BUILDING SITE IN ANY
 QUADRANT. THIS EXPOSURE SHALL ALSO APPLY TO ANY
 BUILDING LOCATED WITHIN EXPOSURE B-TYPE TERRAIN WHERE
 THE BUILDING IS DIRECTLY ADJACENT TO OPEN AREAS OF
 EXPOSURE C-TYPE TERRAIN IN ANY QUADRANT FOR A DISTANCE
 OF MORE THAN 600 FEET (182.9 M). SHORT-TERM (LESS THAN
 TWO YEAR) CHANGES IN THE PRE-EXISTING TERRAIN EXPOSURE,
 FOR THE PURPOSES OF DEVELOPMENT, SHALL NOT BE
 CONSIDERED OPEN FIELDS. WHERE DEVELOPMENT BUILD OUT
 WILL OCCUR WITHIN THREE YEARS AND THE RESULTANT
 CONDITION WILL MEET THE DEFINITION OF EXPOSURE B,
 EXPOSURE B SHALL BE REGULATING FOR THE PURPOSE OF
 PERMITTING. THIS CATEGORY INCLUDES FLAT OPEN COUNTRY,
 GRASSLANDS AND OCEAN OR GULF SHORELINES. THIS CATEGORY
 DOES NOT INCLUDE INLAND BODIES OF WATER THAT PRESENT A
 FETCH OF 1 MILE (1.61 KM) OR MORE OR INLAND WATERWAYS
 OR RIVERS WITH A WIDTH OF 1 MILE (1.61 KM) OR MORE (SEE
 EXPOSURE D).
  
 8) SHOW COMPLIANCE WITH R314.4 THERMAL BARRIER.
 UNLESS OTHERWISE NOTED IN SECTION R314.5, FOAM PLASTIC
 SHALL BE SEPARATED FROM THE INTERIOR OF A BUILDING BY
 AN APPROVED THERMAL BARRIER OF MINIMUM 0.5 INCH (12.7
 MM) GYPSUM WALLBOARD OR AN APPROVED FINISH MATERIAL
 EQUIVALENT TO A THERMAL BARRIER MATERIAL THAT WILL
 LIMIT THE AVERAGE TEMPERATURE RISE OF THE UNEXPOSED
 SURFACE TO NO MORE THAN 250?F (121?C) AFTER 15 MINUTES
 OF FIRE EXPOSURE COMPLYING WITH THE ASTM E 119 STANDARD
 TIME TEMPERATURE CURVE. THE THERMAL BARRIER SHALL BE
 INSTALLED IN SUCH A MANNER THAT IT WILL REMAIN IN PLACE
 FOR 15 MINUTES BASED ON NFPA 286 WITH THE ACCEPTANCE
 CRITERIA OF SECTION R315.4, FM4880, UL 1040, OR UL
 1715.
  
 9) SHOW COMPLIANCE WITH R314.5.3 ATTICS.
 WHERE ATTIC ACCESS IS REQUIRED BY SECTION R807.1 AND
 WHERE ENTRY IS MADE ONLY FOR SERVICE OF UTILITIES, FOAM
 PLASTICS SHALL BE PROTECTED AGAINST IGNITION BY
 1.5-INCH-THICK (38 MM) MINERAL FIBER INSULATION,
 1/4-INCH-THICK (6.4 MM) WOOD STRUCTURAL PANELS,
 3/8-INCH (9.5 MM) PARTICLEBOARD, 1/4-INCH (6.4 MM)
 HARDBOARD, 3/8-INCH (9.5 MM) GYPSUM BOARD, OR
 CORROSION-RESISTANT STEEL HAVING A BASE METAL THICKNESS
 OF 0.016 INCH (0.406 MM) AND THE THERMAL BARRIER
 SPECIFIED IN SECTION R314.4 IS NOT REQUIRED. THE
 IGNITION BARRIER IS NOT REQUIRED WHERE THE FOAM PLASTIC
 INSULATION HAS BEEN TESTED IN ACCORDANCE WITH SECTION
 R314.6.
  
 10) SUBMIT MANUFACTURER'S SPECIFICATIONS AND EVALUATION
 REPORT FOR THE SPRAY FOAM INSULATION. SEE COMMENTS 8
 AND 9 ABOVE.
  
 11) SHOW COMPLIANCE WITH R803.2.3.1 SHEATHING
 FASTENINGS.
 WOOD STRUCTURAL PANEL SHEATHING SHALL BE FASTENED TO
 ROOF FRAMING WITH 8D RING-SHANK NAILS AT 6 INCHES ON
 CENTER AT EDGES AND 6 INCHES ON CENTER AT INTERMEDIATE
 FRAMING. WHERE ROOF FRAMING WITH A SPECIFIC GRAVITY,
 0.42 < G < 0.49 IS USED, SPACING OF RING-SHANK
 FASTENERS SHALL BE 4 INCHES ON CENTER IN NAILING ZONE 3
 FOR 130 MPH OR GREATER DESIGN WIND SPEEDS IN ACCORDANCE
 WITH FIGURE R803.2.3.1.
  
 12) THE TWO HOUR FIRE WALL AND 4 FEET OF 5/8" TYPE X
 GYPSUM BOARD WITH CLASS C ROOF COVERING IS REQUIRED AT
 THE REAR PATIOS. R317.2.1 CONTINUITY.
 THE COMMON WALL FOR TOWNHOUSES SHALL BE CONTINUOUS FROM
 THE FOUNDATION TO THE UNDERSIDE OF THE ROOF SHEATHING,
 DECK OR SLAB AND SHALL EXTEND THE FULL LENGTH OF THE
 COMMON WALL INCLUDING WALLS EXTENDING THROUGH AND
 SEPARATING ATTACHED ACCESSORY STRUCTURES. ALSO SEE
 317.2 AND R317.2.2.
  
 13) THE TRUSS LEDGER NOTES ON THE DETAIL FOR TRUSSES
 PERPENDICULAR TO THE WALL ON SHEET S-2 AND THE NOTES ON
 THE FLOOR FRAMING PLAN ON S-2 DO NOT CORRESPOND. PLEASE
 COORDINATE THE NOTES. R301.1
  
 14) ON SHEET A-3.0 THE WIND PRESSURES FOR SOME OPENINGS
 DO NOT MATCH THE PRESSURES IN THE WINDOW AND DOOR
 SCHEDULE ON THE TYPICAL UNIT DRAWINGS. PLEASE
 COORDINATE. SEE GARAGE DOORS AND WINDOWS B & C.
 R301.2.1
  
 15) ON SHEET A3.0 THE WINDOWS IN THE GARAGES THAT FACE
 TOWARD THE ENTRANCES ARE NOT MARKED FOR WIND PRESSURES.
 R301.2.1
  
 16) ON SHEET A-5 THERE APPEARS TO BE SOME CONFUSION
 REGARDING HANDRAILS AND GUARDS. A HANDRAIL DETAIL IS
 SHOWN WITH A HEIGHT OF 42". PLEASE REVISE. R311.5.6
 HANDRAILS.HANDRAILS SHALL BE PROVIDED ON AT LEAST ONE
 SIDE OF EACH CONTINUOUS RUN OF TREADS OR FLIGHT WITH
 FOUR OR MORE RISERS.R311.5.6.1 HEIGHT. HANDRAIL HEIGHT,
 MEASURED VERTICALLY FROM THE SLOPED PLANE ADJOINING THE
 TREAD NOSING, OR FINISH SURFACE OF RAMP SLOPE, SHALL BE
 NOT LESS THAN 34 INCHES (864 MM) AND NOT MORE THAN 38
 INCHES (965 MM). EXCEPTION: WHEN FITTINGS ARE USED TO
 PROVIDE TRANSITION BETWEEN FLIGHTS, TRANSITION FROM
 HANDRAIL TO GUARDRAIL, OR USED AT THE START OF A STAIR,
 THE HANDRAIL HEIGHT AT THE FITTING SHALL BE PERMITTED
 TO EXCEED THE MAXIMUM HEIGHT. R312.1 GUARDS REQUIRED.
 PORCHES, BALCONIES OR RAISED FLOOR SURFACES LOCATED
 MORE THAN 30 INCHES (762 MM) ABOVE THE FLOOR OR GRADE
 BELOW SHALL HAVE GUARDS NOT LESS THAN 36 INCHES (914
 MM) IN HEIGHT. OPEN SIDES OF STAIRS WITH A TOTAL RISE
 OF MORE THAN 30 INCHES (762 MM) ABOVE THE FLOOR OR
 GRADE BELOW SHALL HAVE GUARDS NOT LESS THAN 34 INCHES
 (864 MM) IN HEIGHT MEASURED VERTICALLY FROM THE NOSING
 OF THE TREADS.
  
 17) ON SHEET A-5 PLEASE CLARIFY THAT THE WINDOW AND
 DOOR ASSEMBLIES ARE REQUIRED TO BE ANCHORED THROUGH THE
 1 X BUCKS INTO THE CONCRETE OR OTHER SUBSTRATE.
 R613.6.1.1 MASONRY, CONCRETE OR OTHER STRUCTURAL
 SUBSTRATE. WHERE THE WOOD SHIM OR BUCK THICKNESS IS
 LESS THAN 1-1/2 INCHES (38 MM), WINDOW AND DOOR
 ASSEMBLIES SHALL BE ANCHORED THROUGH THE MAIN FRAME OR
 BY JAMB CLIP OR SUBFRAME SYSTEM, IN ACCORDANCE WITH THE
 MANUFACTURERS PUBLISHED INSTALLATION INSTRUCTIONS.
 ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO THE
 MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE
 MATERIAL. UNLESS OTHERWISE TESTED, BUCKS SHALL EXTEND
 BEYOND THE INTERIOR FACE OF THE WINDOW OR DOOR FRAME
 SUCH THAT FULL SUPPORT OF THE FRAME IS PROVIDED. SHIMS
 SHALL BE MADE FROM MATERIALS CAPABLE OF SUSTAINING
 APPLICABLE LOADS, LOCATED AND APPLIED IN A THICKNESS
 CAPABLE OF SUSTAINING APPLICABLE LOADS. ANCHORS SHALL
 BE PROVIDED TO TRANSFER LOAD FROM THE WINDOW OR DOOR
 FRAME TO THE ROUGH OPENING SUBSTRATE.
  
 18) THE 2 HOUR FIRE RATED ADJACENT SEPARATION WALLS ARE
 REQUIRED TO BE INSULATED FROM THE BLOCK TO THE SPRAY
 FOAM INSULATION AT THE ROOF. PLEASE SPECIFY INSULATION
 TYPE AND R-VALUE ON THE PLANS AT THE WOOD TRUSS SECTION
 OF THE 2 HOUR FIRE RATED ASSEMBLY. ALSO REVISE ENERGY
 CALCULATION FORMS TO INCLUDE THIS AREA. FBC 13-6.
  
 19) THE INSULATION FOR THE RAISED WOOD FLOOR ABOVE THE
 GARAGE AND PATIO ARE SPECIFIED AS R-13 ON THE PLANS AND
 R-19 ON THE ENERGY CALCULATIONS. PLEASE REVISE. FBC
 13-6.
  
 20) PLEASE SPECIFY THE INSULATION FOR THE RAISED WOOD
 FLOOR ABOVE THE FRONT ENTRY ON THE FLOOR PLANS. FBC
 13-6.
  
 21) THE INSULATION FOR THE WOOD FRAME WALL BETWEEN THE
 GARAGE AND THE CONDITIONED SPACE IS SPECIFIED AS R-11
 ON THE FLOOR PLANS AND R-19 ON THE ENERGY CALCULATION
 FORMS. PLEASE CORRECT. FBC 13-6
  
 22) THE EXTERIOR AND ADJACENT BLOCK WALLS ARE SPECIFIED
 WITH R4.1 ON THE ENERGY CALCS. AND THE ADJACENT BLOCK
 INSULATION IS SPECIFIED AS R-3.0 ON THE PLANS. PLEASE
 REVISE. FBC 13-6.
  
 23) PLEASE SUBMIT TWO COPIES OF THE PRODUCT APPROVALS
 FOR THE SKYTUBE SKYLIGHT SHOWN ON THE PLANS. DCA/FAC
 RULE 9B-72
  
 24) FBC 106.3* CITY AMENDMENTS PRODUCT APPROVALS. THOSE
 PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
  
 25) THE PRODUCT APPROVALS THAT WERE SUBMITTED FOR THE
 CONCRETE ROOF TILE IS INCOMPLETE. SUBMIT TWO COPIES OF
 AN NOA OR OTHER APPROVED EVALUATION REPORT INCLUDING
 INSTALLATION INSTRUCTIONS AS REQUIRED BY DCA RULE
 9B-72. SPECIFY THE METHOD OF ATTACHMENT THAT WILL BE
 USED TO INSTALL THE TILE. R905.3
  
 26) THE PRODUCT APPROVALS FOR THE WINDOW MULLIONS
 SPECIFY A DESIGN PRESSURE OF 48 PSF BASED ON THE CHARTS
 IN THE NOA FOR THE OPENING SIZE AND MULLION LENGTH.
 THIS MAY NOT BE ADEQUATE IF THE EXPOSURE CATEGORY IS
 CHANGED TO C WHICH WILL INCREASE THE DESIGN PRESSURES.
 PLEASE REVIEW.
  
 27) SPECIFY THE MEAN ROOF HEIGHT OF THE STRUCTURE ON
 THE PLANS. MEAN ROOF HEIGHT. THE AVERAGE OF THE ROOF
 EAVE HEIGHT AND THE HEIGHT TO THE HIGHEST POINT ON THE
 ROOF SURFACE, EXCEPT THAT EAVE HEIGHT SHALL BE USED FOR
 ROOF ANGLE OF LESS THAN OR EQUAL TO 10 DEGREES (0.18
 RAD). R301.1
  
 28) R321.1 PREMISES IDENTIFICATION. APPROVED NUMBERS OR
 ADDRESSES SHALL BE PROVIDED FOR ALL NEW BUILDINGS IN
 SUCH A POSITION AS TO BE PLAINLY VISIBLE AND LEGIBLE
 FROM THE STREET OR ROAD FRONTING THE PROPERTY.THE
 BUILDINGS ARE REQUIRED TO HAVE APPROVED ADDRESSES
 BEFORE THE PERMITS WILL BE ISSUED. CONTACT JOHN NGUYEN
 AT 561-822-1239.
  
 29) THE CANVAS AWNINGS SHOWN ON THE ELEVATIONS WILL
 REQUIRE SEPARATE PERMITS AND FEES.
  
 30) THE ROOF FRAMING PLAN ON S-3 SHOWS A GIRDER TRUSS
 THAT IS ATTACHED TO THE TRUSS ASSEMBLY COMPRISING THE 2
 HOUR FIRE RATED SEPARATION WALL. EXPLAIN HOW THIS
 DESIGN WILL NOT AFFECT THE FIRE RATING OF THE LISTED
 ASSEMBLY. PROVIDE DETAILS. R317.2
  
 31) THE NUMBER OF 10D X 1-1/2" NAILS FOR THE SIMPSON
 HETAL 20 AND HETA 16 CONNECTORS SHOULD BE (10) RATHER
 THAN THE (9) SPECIFIED IN THE TRUSS SCHEDULE ON S-3 FOR
 THE UPLIFT LOADS SPECIFIED. SEE 2008 SIMPSON CATALOG.
  
 32) ON S-3 THE KEY FOR THE GYPSUM BOARD UNDER THE ROOF
 DECK HAS 1/2" TYPE X AND R 317.2.2 REQUIRES 5/8" TYPE
 X. PLEASE CORRECT.
  
 33) THE ROOF DESIGN DOES NOT APPEAR TO PROVIDE PROPER
 SEPARATION AT THE GABLES AND HIP ROOFS THAT INTERSECT
 THE PROPERTY LINES. ADDITIONAL DETAILS AND TRUSS
 DRAWINGS ARE REQUIRED IN ORDER TO DETERMINE IF THE
 SEPARATION REQUIREMENTS OF R317.2 HAVE BEEN COMPLIED
 WITH.
  
 34) THE GABLE ROOF OVERHANGS CAN NOT EXTEND BEYOND THE
 PROPERTY LINES. R302.1 EXTERIOR WALLS.EXTERIOR WALLS
 SEPARATED BY LESS THAN 6 FEET (1828 MM) SHALL HAVE NOT
 LESS THAN A ONE-HOUR FIRE-RESISTIVE RATING WITH
 EXPOSURE FROM BOTH SIDES. PROJECTIONS SHALL NOT EXTEND
 TO A POINT CLOSER THAN 4 FEET (1220 MM) FROM AN
 ADJACENT PROJECTION OR WALL.
  
 35) THE VALUE OF THE PRODUCT IS LOW AND HAS BEEN
 ADJUSTED. ADDITIONAL FEES OF $ 2877.30 ARE DUE. FBC
 108.3* CITY AMENDMENTS.
  
 36) IF THE PROJECT IS INTENDED TO BE "MASTERED" SUCH
 THAT ALL PERMIT DOCUMENTS DO NOT HAVE TO SUBMITTED WITH
 THE PERMIT APPLICATIONS FOR EACH INDIVIDUALLY PERMITTED
 TOWNHOUSE UNIT, PLEASE KNOW THAT ALL SUCH PERMITS MUST
 BE APPLIED FOR PRIOR TO THE IMPLEMENTATION OF THE 2007
 FLORIDA BUILDING CODE ON MARCH 1, 2009. THE PROJECT
 WILL NEED TO BE "RE-MASTERED" TO COMPLY WITH THE 2007
 FBC AT THAT TIME.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]