2009-01-13 15:00:39DENIED
 REFERENCE:
 FBC-2004 PLUMBING
  
 1. SHT PE.1 NEW SANITARY RISER DIAGRAM DOES NOT MEET
 CODE REQUIREMENTS. THE TUB, SHOWER, AND WASH MACHINE
 SHALL BE TRAPPED. SECTION 1002.1. THE WASH MACHINE
 REQUIRES A STANDPIPE PER SECTION 1002.1 & SHALL CONFORM
 TO SECTION 802.4. THE RISER INDICATES TRAPS FOR THE LAV
 UNDERGROUND. THE TRAPS SHALL BE PLACED AS CLOSE AS
 POSSIBLE TO THE FIXTURE OUTLET AND THE VERTICLE
 DISTANCE FROM THE FIXTURE OUTLET TO THE TRAP WEIR SHALL
 NOT EXCEED 24 INCHES. SECTION 1002.1. PLEASE SEE RED
 LINE INFORMATION ON ONE SET OF PLANS AND CORRECT PLANS
 SO THEY MEET THESE CODE REQUIREMENTS.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.