Date |
Text |
2008-11-26 13:40:47 | BUILDING PLAN REVIEW |
| PERMIT: 08110321 |
| ADD: 7600 S. DIXIE HWY |
| CONT: LB ROWE INC. |
| TEL: (561)835-1499 |
| FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| W/ 2007 FBC REVISIONS |
| * WEST PALM BEACH AMENDMENTS |
| |
| 11-26-08 |
| REVIEW: 1 |
| ACTION: DENIED |
| |
| 1) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| & REMOVE & REPLACE ANY PAGES AS NECESSARY. A |
| TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT |
| NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, |
| IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE |
| CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. |
| THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| |
| 2) THE DESCRIPTION ON THE APPLICATION DOES NOT MATCH |
| THE PLANS. THE APPLICATION SHALL DESCRIBE THE PROJECT |
| IN DETAIL SO THAT THE PLAN REVIEWERS MAY GET A BETTER |
| UNDERSTANDING OF THE WORK INVOLVED WITH THE PROJECT. IF |
| THE OCCUPANCY TYPE IS CHANGED, WHICH THE PLANS SHOW, |
| PLEASE CHECK THE BOX ON THE APPLICATION. |
| |
| 3) SHEET A-1.01 NOTE #16 STATE NEW FLOORING TRANSITION; |
| PLEASE PROVIDE A CROSS SECTION DETAIL DRAWING OF THE |
| FLOOR AREA WHERE THE TRANSITION TAKES PLACE. THE |
| CHANGES IN LEVEL SHALL BE IN ACCORDANCE WITH FBC |
| 11-4.5.2. THE PLANS NEED TO INDICATE THE ACCESSIBLE |
| PARKING AND ROUTE TO THE BUILDING. FBC 11-4.6.2 |
| |
| 4) SHEET A-0.00: THE LIFE SAFETY PLANS DOORS DO MEET |
| THE REQUIREMENTS OF FBC 1041.2.1 WHICH STATES EXIT |
| ACCESS DOORS SHALL BE PLACED A DISTANCE APART NOT LESS |
| THAN ONE- HALF OF THE OVERALL DIAGONAL DIMENSION OF THE |
| BUILDING AREA. THERE ARE OTHER EXIT DOORS SHOWN ON THE |
| PLANS, HOWEVER, THE DRAWINGS DO NOT INDICATE IF THEY |
| LEAD TO A PUBLIC WAY WHICH SHALL BE UN-OBSTRUCTED |
| INCASE OF EMERGENCY. |
| |
| 5) THE VALUE ON THE PERMIT APPLICATION IS LOW. THE |
| VALUE SHALL BE THE TOTAL COST INCLUDING ELECTRIC, |
| PLUMBING, INTERIOR FINISHES, ARCHITECTURAL DESIGN FEES, |
| MARKETING COST AND OVERHEAD AND PROFIT. OUR VALUATION |
| REFERENCE IS ICC (BVD) MARSHALL-SWIFT AND MEANS COST |
| ANALYSIS SERVICES 108.3* PLEASE INDICATE A FAIR MARKET |
| VALUE ON THE APPLICATION. |
| |
| 6) FBC106.1.1 CONSTRUCTION DOCUMENTS SHALL BE OF |
| SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE & |
| EXTENT OF THE WORK PROPOSED & SHOW IN DETAIL THAT IT |
| WILL CONFORM TO THE PROVISIONS OF THIS CODE AND |
| RELEVANT LAWS, ORDINANCES, AND RULES AND REGULATIONS AS |
| DETERMINED BY THE BUILDING OFFICIAL. |
| |
| MYRON JACOBS |
| BUILDING PLAN REVIEWER |
| PHONE (561)805-6726 |
| FAX (561) 805-6676 |
| [email protected] |
| |