2008-12-06 12:52:03 | REVIEW #: 1ST **PLAN CHECK ONLY** |
| ACTION: P/F |
| |
| FBC 2004 CODE FAMILY W/ 2007 SUPPLEMENTS |
| FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH |
| |
| PLANS HAVE BEEN REVIEWED FOR COMPLIANCE AND PASSED. |
| HOWEVER, PLANS HAVE ONLY BEEN SUBMITTED FOR PLAN |
| REVIEW. NO PERMIT APPLICATION HAS BEEN SUBMITTED. PLANS |
| WILL REMIAN IN FAILED STATUS PENDING SUBMISSION OF |
| PERMIT APPLICATION. |
| |
| NOTE: ENERGY CALCULATIONS WERE NOT REVIEWED FOR CODE |
| COMPLIANCE. IT IS NOT CLEAR AT THIS TIME WHETHER THIS |
| WORK QUALIFIES AS A "RENOVATION" AS DEFINED IN FBCB |
| 13-202. IF THIS PROJECT IS NOT A RENOVATION UNDER THIS |
| DEFINITION, SEE FBCB 13-101.6 BELOW FOR MINIMUM |
| REQUIREMENTS. ENOUGH INFORMATION HAS BEEN PROVIDED ON |
| PLANS TO DEMONSTRATE COMPLIANCE WITH THE REQUIREMENTS |
| OF FBCB 13-101.6. THEREFORE, NO ENERGY OR COOLING LOAD |
| CALCULATIONS ARE REQUIRED. |
| |
| 13-101.6 BUILDING SYSTEMS. |
| THERMAL EFFICIENCY STANDARDS ARE SET FOR THE FOLLOWING |
| BUILDING SYSTEMS WHERE NEW PRODUCTS ARE INSTALLED OR |
| REPLACED IN EXISTING BUILDINGS, AND FOR WHICH A PERMIT |
| MUST BE OBTAINED. SUCH SYSTEMS SHALL MEET THE MINIMUM |
| EFFICIENCIES ALLOWED FOR THAT SYSTEM ON FORM 400C FOR |
| COMMERCIAL BUILDINGS AND ON FORM 600C FOR RESIDENTIAL |
| BUILDINGS. |
| 1. HEATING, VENTILATING OR AIR CONDITIONING SYSTEMS; |
| 2. SERVICE WATER OR POOL HEATING SYSTEMS; |
| 3. ELECTRICAL SYSTEMS AND MOTORS; |
| 4. LIGHTING SYSTEMS. |
| EXCEPTIONS: |
| 1. WHERE PART OF A FUNCTIONAL UNIT IS REPAIRED OR |
| REPLACED. FOR EXAMPLE, REPLACEMENT OF AN ENTIRE HVAC |
| SYSTEM IS NOT REQUIRED BECAUSE A NEW COMPRESSOR OR |
| OTHER PART DOES NOT MEET CODE WHEN INSTALLED WITH AN |
| OLDER SYSTEM. |
| 2. WHERE EXISTING COMPONENTS ARE UTILIZED WITH A |
| REPLACEMENT SYSTEM, SUCH AS AIR DISTRIBUTION SYSTEM |
| DUCTS OR ELECTRICAL WIRING FOR LIGHTS, SUCH COMPONENTS |
| OR CONTROLS NEED NOT MEET CODE IF MEETING CODE WOULD |
| REQUIRE THAT COMPONENT?S REPLACEMENT. |
| 3. REPLACEMENT EQUIPMENT THAT WOULD REQUIRE EXTENSIVE |
| REVISIONS TO OTHER SYSTEMS, EQUIPMENT OR ELEMENTS OF A |
| BUILDING WHERE SUCH REPLACEMENT IS A LIKE-FOR-LIKE |
| REPLACEMENT, SUCH AS THROUGH-THE-WALL CONDENSING UNITS |
| AND PTACS, CHILLERS, AND COOLING TOWERS IN CONFINED |
| SPACES. |
| 4. HVAC EQUIPMENT SIZING CALCULATIONS ARE NOT REQUIRED |
| FOR SYSTEMS INSTALLED IN EXISTING BUILDINGS NOT MEETING |
| THE DEFINITION OF RENOVATION IN SECTION 202. |
| |