2008-11-07 11:54:01 | ****CORRECTIONS**** |
| ROBERT MCDOUGAL, BUILDING PLANS EXAMINER |
| 561-805-6714 [email protected] |
| |
| 2004 FLORIDA BUILDING CODE & |
| CITY OF WEST PALM BEACH AMENDMENTS TO THE 2004 FBC |
| |
| ROOFING PERMIT; ONLY CHECKED ITEMS APPLY |
| |
| ____ 1.) EFFECTIVE OCTOBER 1, 2007, SECONDARY WATER |
| BARRIER REQUIRED FS553.844(5)(A). PROVIDE INFORMATION |
| (PRODUCT APPROVAL OR SPECIFICATIONS) TO SHOW HOW YOU |
| WILL COMPLY WITH THIS REQUIREMENT. INFORMATION IS |
| AVAILABLE AT WWW.BOAF.NET, HURRICANE MITIGATION. |
| |
| ____ 2.) CONTRACTOR IS TO PROVIDE THE FOLLOWING |
| INFORMATION ON THE APPLICATION, SEE ATTACHED POLICY; |
| MEAN ROOF HEIGHT, ROOF PITCH, ROOF DECK TYPE, AREA OF |
| EACH ROOF TYPE |
| |
| ____ 3.) FLORIDA STATE OR LOCAL PRODUCT APPROVAL |
| REQUIRED IN ADDITION TO THE EVALUATION REPORT |
| SUBMITTED, FAC9B72. WWW.FLORIDABUILDING.ORG |
| |
| __X___ 4.) FOR THE FLAT ROOF, SELECT THE APPROVED |
| ASSEMBLY YOU ARE USING. ALSO INDICATE WHICH FASTENER |
| YOU ARE USING IF THE OPTIONS HAVE DIFFERENT PRESSURE |
| LIMITATIONS. |
| |
| _____ 5.) FOR THE FLAT ROOF, SPECIFY THE ENHANCED |
| FASTENING FOR CORNER AND PERIMETER ZONES. THIS IS TO BE |
| EITHER WRITTEN ON THE PRODUCT APPROVAL OR SUBMITTED ON |
| LETTERHEAD, TWO SETS (NOT WRITTEN ON THE RESUB SHEET). |
| |
| ____ 6.) ON THE TILE PRODUCT APPROVAL, INDICATE WHICH |
| METHOD OF ATTACHMENT YOU ARE USING. IF YOU SELECT FOAM |
| ADHESIVE, PRODUCT APPROVALS REQUIRED FAC9B72. |
| |
| __X__ 7.) SEE PRODUCT LIMITATION #7. SUBMIT RAS 117 |
| CALCULATIONS PREPARED BY AN ARCHITECT, ENGINEER, OR |
| REGISTERED ROOF CONSULTANT REQUIRED FOR ENHANCED |
| FASTENING. (IF NOT REQUIRED BY NOA, SEE #5 ABOVE) |
| |
| __X__ 8.) THE NOA THAT WAS SUBMITTED (NOA NO: |
| 03-0501.02) IS EXPIRED. SUBMIT CURRENT PRODUCT |
| APPROVALS. |
| |
| __X__ 9.) THE VALUE FOR THE WORK LISTED ON THE |
| APPLICATION IS LOW FOR 1688 SQFT. IT HAS BEEN ADJUSTED |
| TO $8946.00, ADDITIONAL FEES ARE DUE. |
| |
| |
| PROVISO ? MECHANICAL EQUIPMENT TO COMPLY WITH FBC |
| EB511, FBC1509.7. |
| |
| |
| |