Plan Review Notes
Plan Review Notes For Permit 08100509
Permit Number 08100509
Review Stop B
Sequence Number 1
Notes
Date Text
2008-10-23 15:45:522004 FBC W/2007 REVISIONS
 INSTALL FLAT ROOF SYSTEM
  
 DENIED BY BUILDING
  
 1) SUBMIT TWO COPIES OF SIGNED AND SEALED RAS 117
 CALCULATIONS FROM AN ARCHITECT, ENGINEER OR REGISTERED
 ROOF CONSULTANT FOR ENHANCED FASTENING AT PERIMETER AND
 CORNER AREAS. SEE LIMITATION #7 ON PAGE 39 OF THE
 CERTAINTEED MODIFIED ROOFING SYSTEM NOA NO. 08-0227.09.
 SEE FBC TABLE R301.2(2) FOR UPLIFT PRESSURES IN EXPOSUE
 B. CORNERS HAVE PRESSURES OF -89.0 PSF.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]