Plan Review Notes
Plan Review Notes For Permit 08100424
Permit Number 08100424
Review Stop B
Sequence Number 1
Notes
Date Text
2008-11-10 09:25:27BUILDING PLAN REVIEW
 PERMIT: 08100424
 ADD: 3960 WEST HAMILTON KEY DRIVE.
 CONT: CRAFT MASTER CUSTOM POOLS
 TEL: (561)798-7929
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW: 1ST
 ACTION: DENIED
  
 1) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE & REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 2) FL S S 713.13 NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT. NOTE: 713.13(2) IF THE
 WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT
 ACTUALLY COMMENCED WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6)
 THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE
 CONSTRUCTION SITE BEFORE THE FIRST INSPECTION.
  
 3) FBC 424.1.3.1 POOL WET DECKS SHALL BE CONSTRUCTED OF
 CONCRETE OR OTHER NONABSORBENT MATERIAL HAVING A SMOOTH
 SLIP-RESISTANT FINISH. THE DECK TYPE INDICATED ON THE
 PLANS IS "MARBLE" WHICH IS VERY SLIPPERY WHEN WET.
 PROVIDE INFORMATION SHOWING HOW THE MARBLE WILL MEET
 THIS REQUIREMENT. WITH THE MARBLE DECK THE VALUATION OF
 THE POOL WILL BE MORE THAN WHAT IS STATED ON THE
 APPLICATION. CLARIFY.
  
 4) FBC 424.1.3.1.2 POOL WET DECKS SHALL BE UNIFORMLY
 SLOPED AT A MINIMUM OF 2 PERCENT TO A MAXIMUM OF 4
 PERCENT AWAY FROM THE POOL OR TO DECK DRAINS TO PREVENT
 STANDING WATER.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 [email protected]
  
  