2008-10-27 11:14:13BUILDING PLAN REVIEW
 PERMIT: 08100329
 ADD: 909 3RD ST
 CONT: NEWBOLD CONSTRUCTION
 TEL: (561)644-5764
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW
 ACTION: DENIED
  
 1A) INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE
 INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 1B) INFORMATIONAL FL S S 713.13 NOTICE OF COMMENCEMENT,
 TO BE FILED WITH THE CLERK OF THE COURT. NOTE:
 713.13(2) IF THE WORK DESCRIBED IN THE NOTICE OF
 COMMENCEMENT IS NOT ACTUALLY COMMENCED WITHIN 90 DAYS
 AFTER THE RECORDING THEREOF, SUCH NOTICE IS NULL &
 VOID. NOTE: 713.13(6) THE POSTING OF THE NOTICE OF
 COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST
 INSPECTION.
  
 1C) INFORMATIONAL: PLANS SUBMITTED FOR PERMIT (FIRST
 TIME REVIEW) AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO
 THE 2004 FBC BUILDING WITH THE 2007 SUPPLEMENTS, PLEASE
 UPDATE SHEET 1 TO THE 2007 SUPPLEMENTS TO THE 2004 FBC
  
 2) SHEET 2 INDICATES A 4HR FIRE RATED WALL AND DOORS
 CREATING A NEW BUILDING NOT AN ADDITION, IN DOING SO
 PLEASE PROVIDE FIRE RESISTANCE RATED ASSEMBLIES FOR
 THROUGH -PENETRATIONS. 712.3/ 712.3.1
  
 3) SHEET 2 & 3 INDICATES THE USE OF 8 INCH BLOCK AND A
 RAKE BEAM AT THE FIRE WALL BUT THE FOUR HR RATING DOES
 NOT GO THROUGH THE ROOF NOR THE ROOF OVERHANG, PLEASE
 REVIEW SECTION 705.5.2 HORIZONTAL PROJECTING ELEMENTS,
 ALSO REVIEW THE CODE COMMENTARY.
  
 4) 110.2* W. P. B. ADMINISTRATIVE CODE, INFORMATION
 THAT IS REQUIRED FOR RECORD KEEPING & FOR CERTIFICATE
 OF OCCUPANCY:
 A) THE EDITION OFTHE CODE UNDER WHICH THE PROJECT IS
 DESIGNED.
 B) THE TYPE OF CONSTRUCTION AS DEFINED IN TABLE 503,
 CHAPTER 6, TABLE 601.
 D) THE OCCUPANT LOAD, SEE 1004.
 E) IF AN AUTOMATIC SPRINKLER SYSTEM IS PROVIDED
 F) WHETHER THE SPRINKLER SYSTEM IS REQUIRED.
 G) ANY SPECIAL STIPULATIONS & CONDITIONS OF THE
 BUILDING PERMIT
 H) SQ. FT. FOOTPRINT
  
 5) PLANS DO NOT INDICATE WHAT THE FLOOR FINISH WILL BE,
 THE ENRGY CALCULATIONS INPUT DATA REPORT INDICATES 392
 SQ FT OF CARPET AND PADDING, AT WHAT LOCATION?
 ADDITIONAL INFORMATION REQUIRED.106.1.2.
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)659-8026
 E-MAIL: [email protected]
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
  
  
  
  