Plan Review Notes For Permit 08090669 |
Permit Number |
08090669 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2008-09-27 11:04:58 | | | DENIED | | | | 1) THE 2006 AMENDMENTS TO THE 2004 FBC REQUIRE | | BUILDINGS LOCATED WITHIN EXP B TYPE TERRAIN THAT IS | | DIRECTLY ADJACENT TO EXP C TYPE TERRAIN SUCH AS OPEN | | GOLF COURSES AND BODIES OF WATER FOR A DISTANCE OF 600 | | FEET OR MORE IN ANY QUADRANT TO BE IN AN EXP C | | CATEGORY. DUE TO THIS CRITERIA THE DOOR PRODUCT IS | | REQUIRED TO MEET DESIGN PRESSURES OF +40.8 -53.2, THE | | PRODUCT APPROVAL SUBMITTED FOR DOUBLE OUTSWING ONLY | | MEETS -47 PSF | | | | 2) PLEASE BE AWARE THAT THIS PRODUCT IS NOT IMPACT | | RATED AND ALTHOUGH THE CODE DOES NOT REQUIRED SHUTTERS | | FOR A CHANGE OUT ON AN EXISTING BUILDING WHEN LESS THAN | | 25% OF THE OPENINGS ARE CHANGED IN A 12 MONTH PERIOD, | | NO HOMEOWNER INSURANCE DISCOUNT WILL BE AVAILABLE | | UNLESS THESE GLAZED OPENINGS ARE PROTECTED. | | | | BLDG PLAN REVIEW | | ADRIAN MORSE | | 561-805-6716 | | |
|