2008-10-06 14:12:11 | ****CORRECTIONS**** |
| SAMANTHA HILL, BUILDING PLANS EXAMINER |
| 561-805-6724 [email protected] |
| FBC FLORIDA BUILDING CODE 2004 |
| FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL |
| |
| SHUTTER PERMIT APPLICATION, ONLY CHECKED ITEMS APPLY |
| |
| ____ 1. PROVIDE BUILDING HEIGHT ON THE PLAN. DESIGN |
| PRESSURES FOR BUILDINGS OVER 60FEET ARE REQUIRED TO BE |
| DESIGNED USING ASCE7, FBC1609.1.1 AND MUST BE DONE BY A |
| DESIGN PROFESSIONAL. DOCUMENTS PREPARED BY AN ARCHITECT |
| OR ENGINEER AND SUBMITTED FOR PUBLIC RECORD ARE TO BE |
| SIGNED SEALED ORIGINALS FAC61G15, FAC61G1 16. |
| |
| _XX_ 2. COMPLETE THE ATTACHED INSTALLATION SCHEDULE OR |
| PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN |
| ANOTHER FORMAT, FBC*106. TWO SETS REQUIRED. |
| HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_ |
| INSTALLATION.PDF |
| |
| ____ 3. FLORIDA STATE OR LOCAL PRODUCT APPROVAL |
| REQUIRED, FAC9B72, WWW.FLORIDABUILDING.ORG. |
| |
| ____ 4. SHOW THE EMERGENCY MEANS OF ESCAPE, FBC R310. |
| |
| ____ 5. PROVIDE A FLOOR PLAN SHOWING WHERE THE SHUTTERS |
| WILL BE INSTALLED AND PANEL SIZES WHICH CORRELATES WITH |
| THE INSTALLATION SCHEDULE, ITEM 2 ABOVE. |
| |
| _XX_ 6. REVISE EXPOSURE CATEGORY OR EXPLAIN RATIONALE |
| FOR EXPOSURE B. NOTE THAT THE DEFINITION FOR EXPOSURE C |
| HAS CHANGED EFFECTIVE DECEMBER 8, 2006 FBC1609.4, FBC |
| R301.2.1.4. |
| |
| |