2008-09-29 13:24:03 | BUILDING PLAN REVIEW |
| PERMIT: 08090381 |
| ADD: 150 CLEARWATER DRIVE |
| CONT: CATALFUMO |
| TEL: (561)694-8853 |
| |
| |
| FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| W/ 2007 FBC REVISIONS |
| * WEST PALM BEACH AMENDMENTS |
| |
| REVIEW |
| ACTION: DENIED |
| BUS SHELTER# 5 |
| |
| 1A) INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE |
| INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS |
| NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| COOPERATION. |
| |
| 1B) INFORMATIONAL FL S S 713.13 NOTICE OF COMMENCEMENT, |
| TO BE FILED WITH THE CLERK OF THE COURT. NOTE: |
| 713.13(2) IF THE WORK DESCRIBED IN THE NOTICE OF |
| COMMENCEMENT IS NOT ACTUALLY COMMENCED WITHIN 90 DAYS |
| AFTER THE RECORDING THEREOF, SUCH NOTICE IS NULL & |
| VOID. NOTE: 713.13(6) THE POSTING OF THE NOTICE OF |
| COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST |
| INSPECTION. |
| |
| 1C) INFORMATIONAL: PLANS SUBMITTED FOR PERMIT (FIRST |
| TIME REVIEW) AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO |
| THE 2004 FBC BUILDING WITH THE 2007 SUPPLEMENTS SHEET |
| S-3 NEEDS TO UPDATE SUPPLEMENTS OF THE 2007SUPPLEMENTS. |
| |
| 1D) THE PERMIT APPLICATION UNDER ADDRESS IS INDICATED |
| AS 150 CLEARWATER DRIVE, THIS IS A SITE ADDRESS AND |
| WILL REQUIRE A SEPERATE ADDRESS FOR THE RESTROOMS. |
| PLEASE CONTACT JAMES JUDGE AT (561)822-1226, 106.1.2 |
| ADDITIONAL INFORMATION REQUIRED. |
| |
| 1E) THE PERMIT APPLICATION INDICATES A BUS SHELTER# 1 |
| TO BE CONSTRUCTED. PLANS SUBMITTED ARE TWO SETS OF A6 & |
| A7 AND SEVEN 2OF 65 CIVIL DRAWINGS. SINCE THIS WAS NOT |
| SUBMITTED AS A MASTER PLAN, EACH INDIVIDUAL PERMIT |
| APPLICATION WILL NEED TO SUBMIT 2 SETS OF ALL |
| DOCUMENTS. PLEASE PROVIDE THE REQUIED (2) SETS OF PLANS |
| WITHIN THIS PERMIT APPLICATION FOR COMPLIANCE WITH |
| MINIMUM PLAN REVIEW CRITERIA FOR COMMERCIAL BUILDINGS |
| 106.3.5.1.1. |
| SITE PLAN |
| OCCUPANCY GROUP REQUIREMENTS SHALL BE DETERMINED |
| MINIMUM TYPE OF CONSTRUCTION SHALL BE DETERMINED PLEASE |
| PROVIDE THE MINIMUM BUILDING TYPE CONSTRUCTION. TABLE |
| 503/ TABLE 601 |
| SOILS CONDITION |
| BUILDING ENVELOPE COMPONENTS |
| WIND DESIGN CRITERIA, STRUCTURAL NOTES LOCATED ON SHEET |
| A3 ARE INDICATED ON SHEET A6 BUT NOT INCLUDED. |
| |
| 1F) AS OF 9-29-08 PERMIT FEE S HAVE NOT BEEN PAID, FEES |
| ARE TO BE PAID AT TIME OF PERMIT APPLICATION. FEES OWED |
| ARE $780.52,. CITY CODE OF ORDINANCES18.1(D) ALL PERMIT |
| FEES MUST BE PAID IN FULL AT TIME OF PERMIT |
| APPLICATION. |
| |
| 2) PLEAS E SUBMIT 2 ORIGINALS SIGNED AND SEALED SOILS |
| REPORTS. 1802.2.1 QUESTIONABLE SOIL. WHERE THE |
| SAFE-SUSTAINING POWER OF THE SOIL IS IN DOUBT, OR WHERE |
| A LOAD-BEARING VALUE SUPERIOR TO THAT SPECIFIED IN THIS |
| CODE IS CLAIMED, THE BUILDING OFFICIAL SHALL REQUIRE |
| THAT THE NECESSARY INVESTIGATION BE MADE. SUCH |
| INVESTIGATION SHALL COMPLY WITH THE PROVISIONS OF |
| SECTIONS 1802.4 THROUGH 1802.6 . |
| |
| 3) FL BLD CODE 1609.1.4: COMPONENTS & CLADDING, PROVIDE |
| 2 COPIES, 3 IF THRESHOLD OR RESIDENT INSPECTOR OF |
| PRODUCT TESTING REPORTS, MISSING REPORTS ARE AS |
| FOLLOWS: |
| 3A) GLASS WIND BREAK -FOR WIND, LARGE MISSILE TESTING |
| NOT REQUIED RULE 9B-72 (31) (B) |
| 3B) ROOFING ASSEMBLIES, UNDERLAYMENTS, ROOF TILE |
| ADHESIVES, ROOF TILES AND OR ANY PART OF AN INTEGRAL |
| PART OF ANY ROOFING ASSEMBLY.RULE 9B-72(31)(D). PLEASE |
| CIRCLE THE METHOD OF ATTACHMENT FOR THE MOMENT OF |
| OVERTURNING. 1715.2.1. |
| |
| 4) PRODUCT APPROVALS SUBMITTED WITH PERMIT APPLICATION |
| AFTER OCTOBER 1, 2003 ARE REQUIRED TO COMPLY WITH THE |
| FLORIDA PRODUCT APPROVAL SYSTEM. FOR INFORMATION PLEASE |
| SEE THE STATE WEBSITE AT WWW.FLORIDABUILDING.ORG. |
| PRODUCTS WITH STATEWIDE APPROVAL ARE REQUIRED TO BE |
| SUBMITTED WITH A COVER SHEET THAT LISTS THE PRODUCT |
| IDENTITY NUMBER FROM THE STATE. IF THE PRODUCT DOES NOT |
| HAVE STATEWIDE APPROVAL, SUBMIT AN APPLICATION FOR |
| LOCAL PRODUCT APPROVAL OR SITE SPECIFIC FORM PER RULE |
| 9B-72. SEE ATTACHMENT. WWW.FLORIDABUILDING.ORG |
| |
| 5) WPB ADMIN CODE 106.3* PRODUCT APPROVALS. THOSE |
| PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE |
| REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF |
| RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| |
| 6) PLANS DO NOT PROVIDE INFORMATION ON TERMITE |
| TREATMENT AS PER SECTION 1816.1, OR FOR A VAPOR BARRIER |
| AS REQUIRED IN 1816.1.4. |
| |
| |
| JIM WITMER C. B. O. |
| BUILDING PLAN REVIEW II |
| |
| TEL: (561)805-6715 |
| FAX: (561)659-8026 |