Plan Review Notes
Plan Review Notes For Permit 08090276
Permit Number 08090276
Review Stop B
Sequence Number 2
Notes
Date Text
2008-11-25 08:54:092004 FBC W/2007 REVISIONS
 NSFD
  
 DENIED BY BUILDING
  
 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT WILL
 BE REQUIRED. FS713
  
 2) SHOW COMPLIANCE WITH FBC R302.1 EXTERIOR WALLS.
 EXTERIOR WALLS SEPARATED BY LESS THAN 6 FEET (1828 MM)
 SHALL HAVE NOT LESS THAN A ONE-HOUR FIRE-RESISTIVE
 RATING WITH EXPOSURE FROM BOTH SIDES. PROJECTIONS SHALL
 NOT EXTEND TO A POINT CLOSER THAN 4 FEET (1220 MM) FROM
 AN ADJACENT PROJECTION OR WALL.PROJECTIONS EXTENDING
 INTO THE 6-FOOT (1829 MM) SEPARATION DISTANCE SHALL
 HAVE NOT LESS THAN 1-HOUR FIRE-RESISTIVE CONSTRUCTION
 ON THE UNDERSIDE. THE ABOVE PROVISIONS SHALL NOT APPLY
 TO WALLS WHICH ARE PERPENDICULAR TO A LINE EXTENDING
 FROM THE POINT FROM WHICH THE SEPARATION DISTANCE HAS
 BEEN MEASURED RUNNING AND PARALLEL TO THE PROPERTY
 LINE. THE DISTANCE FROM SOME OF THE STRUCTURE'S WALLS
 TO THE PROPERTY LINES ARE LESS THAN SIX FEET. SUBMIT 2
 SURVEYS OR SITE PLANS THAT SPECIFY THE DISTANCES TO
 STRUCTURES ON ADJACENT PROPERTIES AT THESE LOCATIONS.
  
 3) SHOW COMPLIANCE WITH R302.2 OPENINGS.
 OPENINGS SHALL NOT BE PERMITTED IN THE EXTERIOR WALL OF
 A DWELLING OR ACCESSORY BUILDING THAT IS SEPARATED FROM
 AN ADJACENT BUILDING BY A DISTANCE OF LESS THAN 6 FEET
 (1828 MM). THIS DISTANCE SHALL BE MEASURED
 PERPENDICULAR TO THE LINE USED TO DETERMINE THE
 SEPARATION DISTANCE.
  
 4) SUBMIT MANUFACTURER'S SPECIFICATIONS AND LISTING
 INFORMATION FOR THE VENTLESS LOG GAS HEATER ON THE
 LANAI. A SEPARATE GAS PERMIT WILL BE REQUIRED.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]