2008-09-25 11:09:561) UNTIL A CERTIFIED CONTRACTOR IS SIGNED ON THE
 APPLICATION AND A FAIR CONTRACT VALUE IS INDICATED THE
 PLANS WILL REMAIN IN A FAIL STATUS. THE PLANS SHALL
 STATE THE PRESENT CODE CYCLE FOR WHICH THE PROJECT IS
 DESIGNED.
 PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER
 JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC
 BUILDING WITH THE 2007 SUPPLEMENTS.
  
 2) THE LIGHT POLES DESIGN FOR WIND SHALL BE IN
 ACCORDANCE WITH THESE SECTIONS, AND THE INFORMATION
 SHALL BE SHOWN ON THE DRAWINGS.
 1609.6.2 WIND DESIGN PROCEDURES
 1) THE BASIC WIND SPEED, V, SHALL BE DETERMINED IN
 ACCORDANCE WITH SECTION 1609.3. THE WIND SHALL BE
 ASSUMED TO COME FROM ANY HORIZONTAL DIRECTION.
  
 2) AN IMPORTANCE FACTOR, IW, SHALL BE DETERMINED IN
 ACCORDANCE WTIH SECTION1609.5.
  
 3) AN EXPOSURE CATEGORY SHALL BE DETERMINED IN
 ACCORDANCE WITH 1609.4.
  
 4) A HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENT, *
 SHALL BE DETERMINED FROM TABLE 1609.6.2.1(4)
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 [email protected]