Date |
Text |
2008-09-11 10:20:04 | PLUMBING PLAN REVIEW: |
| DENIED **2ND TIME: |
| |
| PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH |
| 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO |
| CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE |
| (F.A.C.), AND FLORIDA STATUTES (F.S.). |
| |
| THE FOLLOWING COMMENTS ARE NUMBERED TO CORRESPOND WITH |
| THE PREVIOUS PLUMBING PLAN REVIEW COMMENTS AS WELL AS |
| THE DESIGNER'S RESPONSES FOR THE PURPOSE OF CONTINUITY. |
| |
| 1. "OK" COMMENT ADDRESSED. |
| |
| 2. THE KITCHEN SINK CAN NOT DRAIN INTO THE WET VENTED |
| 1/2 BATH. IT MUST DRAIN DOWNSTREAM OF THE 1/2 BATH. PER |
| FBC-2004 PLUMBING SECTION 909.1 WET VENT PERMITTED. |
| |
| **NO COMMENT RESPONSE FROM THE DESIGNER AND THE COMMENT |
| WAS NOT ADDRESSED. THE RESUBMITTED RISER DIAGRAM IS |
| STILL INDICATING THE KITCHEN SINK DRAINING INTO THE 1/2 |
| BATH 2" WET VENT. THE RESUBMITTED PLANS DO NOT INDICATE |
| HOW THE 1/2 BATH WATER CLOSET WASTE AND VENT IS PIPED. |
| PER THE RESUBMITTED DRAWING INDICATING KITCHEN & 1/2 |
| BATH ON THE SANITARY RISER IT IS ASSUMED THAT THE 2" IS |
| THE VENT FOR THE WATER CLOSET. SUBMIT A SANIATRY RISER |
| OF THE 1/2 BATH THAT CLEARLY SHOWS HOW ALL FIXTURES |
| (WATER CLOSET & LAVATORY) ARE PLUMBED CODE COMPLIANT. |
| PER FBC-2004 PLUMBING SECTION 909.1 WET VENT PERMITTED, |
| SECTION 701.1 SCOPE AND SECTION 901.1 SCOPE. |
| |
| 3. "OK" COMMENT ADDRESED. |
| |
| 4. "OK" COMMENT ADDRESSED. |
| |
| 5. NOTE: ALL PLANS, SPECIFICATIONS, AND ACCOMPANYING |
| DATA BEING FILED FOR PUBLIC RECORD SHALL CONTAIN THE |
| PRINTED NAME OF THE RESPONSIBLE PERSON WITH THE |
| ORIGINAL SIGNATURE AND DATE ON SUCH INFORMATION. PER |
| (W.P.B. AS AMENDED) SECTION *106.3.4.3. |
| |
| **NO COMMENT RESPONSE AND COMMENT WAS PARTIALLY |
| ADDRESSED. TWO OF THE THREE RESUBMITTED SANITARY RISER |
| DIAGRAMS HAVE PHOTO COPIED SIGNATURES OF THE PERSON |
| TAKING RESPONSIBILITY OF THE DRAWINGS. ORIGINAL |
| SIGNATURES ARE REQUIRED. PER (W.P.B. AS AMENDED) |
| SECTION 106.3.4.3. |
| |
| ********IMPORTANT INFORMATION******** |
| WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE |
| OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW |
| PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A |
| TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT |
| NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, |
| IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. |
| THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| |
| END OF COMMENTS: |
| |
| REVIEW BY: MIKE PERSON |
| PLUMBING PLANS EXAMINER |
| PHONE= (561) 805-6730 |
| FAX= (561) 805-6731 |
| E-MAIL= [email protected] |
| |
| |