Plan Review Notes
Plan Review Notes For Permit 08080467
Permit Number 08080467
Review Stop B
Sequence Number 1
Notes
Date Text
2008-09-02 16:39:28BUILDING PLAN REVIEW
 PERMIT: 08080467
 ADD: 4475 MEDICAL CENTER WAY# 2
 CONT: LEIGHTON MCGINN
 TEL: (561)262-6381
  
 SEPTEMBER 02,2008
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW
 ACTION: DENIED
  
 1A) INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE
 INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 1B) INFORMATIONAL FL S S 713.13 NOTICE OF COMMENCEMENT,
 TO BE FILED WITH THE CLERK OF THE COURT. NOTE:
 713.13(2) IF THE WORK DESCRIBED IN THE NOTICE OF
 COMMENCEMENT IS NOT ACTUALLY COMMENCED WITHIN 90 DAYS
 AFTER THE RECORDING THEREOF, SUCH NOTICE IS NULL &
 VOID. NOTE: 713.13(6) THE POSTING OF THE NOTICE OF
 COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST
 INSPECTION.
  
 2) SHEET A1 PLAN NOTE# 1 INDICATES SECTION 704.2.1.4
 THIS SECTION IS FROM THE 2001 FBC PLEASE CORRECT TO THE
 2004 FBC SECTION 712.5.
  
 3) SHEET A3 ROOM FINISHES INDICATES THE RESTROOM WALLS
 ARE TO RECEIVE AN EPOXY PAINT FINISH.PLEASE REVIEW
 SECTION 1210.2 WALLS. WALLS WITHIN 2 FEET (610 MM) OF
 URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH, HARD,
 NONABSORBENT SURFACE, TO A HEIGHT OF 4 FEET (1219 MM)
 ABOVE THE FLOOR, AND EXCEPT FOR STRUCTURAL ELEMENTS,
 THE MATERIALS USED IN SUCH WALLS SHALL BE OF A TYPE
 THAT IS NOT ADVERSELY AFFECTED BY MOISTURE.
  
 4) DISCREPANCY BETWEEN T.1 AND THE LIFE SAFETY PLAN
 SHEET T.1 DOES NOT INDICATE THIS BUILDING IS FIRE
 SPRINKLERED WHERE AS THE LS SHEETS INDICATE THIS
 BUILDING TO BE FULLY FIRE SPRINKLERED. 106.1.2
 ADDITIONAL INFORMATION REQUIRED.
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)659-8026
 E-MAIL: [email protected]
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
  
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved