Plan Review Notes
Plan Review Notes For Permit 08080212
Permit Number 08080212
Review Stop B
Sequence Number 1
Notes
Date Text
2008-08-21 17:30:28RESIDENTIAL (R3) ADDITION AND RENOVATION BUILDING
 REVIEW CHECKLIST.
 REVIEW UNDER FBC 2004 WITH 2007 REVISIONS.
  
 1- BRING PLANS TO PALM BEACH COUNTYTO VERIFY IF
 IMPACT FEES ARE DUE. BRING BACK STAMPED PLANS AND COPY
 OF PAID RECEIPT IF FEES ARE DUE.
  
 2- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC.
 13-101.2.2 FBC 2004.
 NOTE: PLEASE MAKE SURE CORRECT REVISED FORM IS USED
 AND IS FILLED COMPLETELY TO AVOID UNNECESSARY DELAYS.
  
 3-PLANS TO SPECIFY SAFETY GLASS FOR WINDOWS BY
 BREAKFAST AREA AND BY SHOWER AREA AS REQUIRED BY SEC.
 R308.4 OF 2004 FLORIDA RESIDENTIAL CODE.
  
 4- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9B-72 FOR:
 A)FIXED ARCHED WINDOW. SEE PLANS.
  
 B) WINDOW MULLION. SEEPLANS.
  
 C) SINGLE HUNG WINDOWS. NEED TO PROVIDE PRODUCT
 APPROVAL THAT MEETS ALL THE DESIGN PRESSURES CALCULATED
 FOR WINDOW W2.
  
 D) FLAT ROOF:
 (1) SPECIFYSPECIFIC APPROVED ASSEMBLY TO BE USED.
  
 (2) SPECIFY SPECIFIC BASE SHEET FASTENING OPTION TO
 BE USED.
 (3) PROVIDE RAS 117 CALCULATIONS FOR NAIL ENHANCING
 AT PERIMETER &CORNER AREAS AS REQ'D BY GENERAL
 LIMITATION #7 ONNOA 07-0111.03.
  
 5- SHEET SP-1:DESIGN CRITERIA CALLS FOR EXPOSURE "C",
 WHILE STRUCTURAL SHEETSS-1 AND S-3 CALL FOR EXPOSURE
 "B". REVISE AS REQUIRED TO MATCH.
  
 6- SHEET A-1:
 A) CRAWL SPACE VENTILATION TO COMPLY WITH THE
 MINIMUM SIZE,LOCATION AND ACCESS REQUIREMENTS OF SEC.
 R408 OF 2004 FLORIDA RESIDENTIAL CODE. REVISE AS
 REQUIRED.
 NOTE:REVISE EXTERIOR ELEVATIONS TO REFLECT LOCATION
 OF VENTS AS WELL.
  
 B) REVISE UNDER FLOOR VENTILATION NOTES:REFERENCE
 CODE SECTIONSFROM THE FLORIDA RESIDENTIAL CODE, NOT
 FROM THEFBC.
  
 C) REVISE RISER TREAD RATIO TO COMPLY WITH SEC.
 R311.5.3.2 OF 2004 FLORIDA RESIDENTIAL CODE.
 NOTE: REVISE THIS INFORMATION ON STRUCTURAL DRAWINGS
 ALSO.
  
 7- SHEET A-2:
 A) EMERGENCY ROOF DRAIN SCUPPERS TO COMPLY WITH
 SEC. R903.4.1 OF 2004 FLORIDA RESIDENTIAL CODE. SPECIFY
 HEIGHT FROM THE FINISHED ROOF COVERING.
  
 B) REVISE ROOF DRAINAGE NOTES:REFERENCE CODE
 SECTIONSFROM THE 2004 FLORIDA RESIDENTIAL CODE, NOT
 THE 2004 FBC.
  
 8- SHEET A-4:
 A) TYPICAL WALL SECTION:
 (1) CLARIFY WHYVENTING IS NOT REQUIRED. SPECIFY
 WHICH CODE SECTIONS STATES THAT NO VENTILATION IS
 REQUIRED ON ROOF.ACCORDING TO SEC. R806 OF 2004
 FLORIDA RESIDENTIAL CODECROSS VENTILATION IS
 REQUIRED. SPECIFYIN PLANS/ELEVATIONS SIZE AND
 LOCATION OF CROSS VENTILATION.
  
 (2) SPECIFYHOW PROVIDING PROTECTION TO THE FLOOR
 JOIST AS REQUIRED BY SEC. R319 .1 OF 2004 FLORIDA
 RESIDENTIAL CODE.
  
 (3) REVISE SIZE OF FLOOR JOIST TO MATCH SIZE SHOWN
 ON STRUCTURAL PLANS.
  
 9- SHEET S-2:REVISE NOTES ON TYPICAL WIND PRESSURE
 BOX SHOWN ON THE FLOOR PLAN D.DISTANCE "A" TO BE
 4'-0" MIN. AS REQUIRED BY NOTE A ON FIGURE R301.2(8) OF
 2004 FLORIDA RESIDENTIAL CODE.
 ***NOTE:REVISE SAME INFORMATION ON SHEET S-3.
  
 10- OWES $5.02 FOR RADON FEES FOR NEW ADDITION.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712