Plan Review Notes
Plan Review Notes For Permit 08080141
Permit Number 08080141
Review Stop P
Sequence Number 1
Notes
Date Text
2008-08-15 15:24:53PLUMBING PLAN REVIEW:
 DENIED:
  
 PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH
 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO
 CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.), AND FLORIDA STATUTES (F.S.).
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE.
  
 1. THERE ARE TWO DIFFERENT VENT PIPE SIZES BEING
 INDICATED FOR THE ENTRAPMENT AVOIDANCE. THE ENTRAPMENT
 AVOIDANCE VENT PIPE ANALYSIS-MAXIMUM LENGTH DETAIL IS
 INDICATING A 1" VENT FOR THE DETAIL, HOWEVER SHEET 2,
 POOL PIPING DIAGRAM IS INDICATING AN 1-1/2" VENT PIPE.
 PLEASE CORRELATE THE PLAN SHEET AND DETAIL VENT PIPING
 SIZE. PER (W.P.B. AS AMENDED) SECTION 106.1.1
 INFORMATION ON CONSTRUCTION DOCUMENTS AND FBC-2004
 RESIDENTIAL, CHAPTER 41, SECTION R4101.6 ENGINEERING
 DESIGN.
  
 2. A POOL HEATER IS BEING INDICATED ON THE PERMIT
 APPLICATION AND ON SHEET 2, PLUMBING PIPING DIAGRAM,
 HOWEVER IT IS NOT BEING INDICATED ON THE SPECIFICATION
 POOL EQUIPMENT. PLEASE CORRECT THIS ON THE RESUBMITTAL.
 PER (W.P.B. AS AMENDED) SECTION 106.1.1 INFORMATION ON
 CONSTRUCTION DOCUMENTS AND FBC-2004 RESIDENTIAL,
 CHAPTER 41, SECTION R4101.6 ENGINEERING DESIGN.
  
 3. FBC-2004 SEC. 424.2.14.1, OR
 FBCR-2004 SEC. R4101.14.1 SWIMMING POOL
 WATER HEATERS SHALL BEAR THE LABEL OF A
 RECOGNIZED TESTING AGENCY. (MANUFACTURE
 SHEETS REQUIRED, PLEASE SUBMIT)
  
 4. FBC-2004 SEC. 424.2.14.2, OR
 FBCR-2004 SEC. R4101.14.2 WATER
 RETENTION, PROVIDE A POSITIVE MEANS OF
 RETAINING WATER IN THE HEATER WHEN PUMP
 IS SHUT OFF.(MANUFACTURE SHEETS
 REQUIRED, PLEASE SUBMIT)
  
 5. FBC-2004 SEC. 424.2.7.2, OR
 FBCR-2004 SEC. R4101.7.2 PUMPS AND
 EQUIPMENT SHALL BE MOUNTED ON A
 SUBSTANTIAL BASE IN A MANNER THAT WILL
 ELIMINATE STRAIN ON PIPING.SLAB SHALL
 BE A NOMINAL 4" THICK. (DETAIL REQUIRED)
  
 ********IMPORTANT INFORMATION********
 WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE
 OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW
 PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 PHONE= (561) 805-6730
 FAX= (561) 805-6731
 E-MAIL= [email protected]


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved