2008-08-05 09:41:24PLUMBING PLAN REVIEW:
 DENIED:
  
 PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH
 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO
 CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.), AND FLORIDA STATUTES (F.S.).
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE.
  
 1. SHEET A-1 FLOOR PLAN: CLEARLY IDENTIFY ALL PLUMBING
 FIXTURES ON THE FLOOR PLAN. PER FBC-20004 PLUMBING
 SECTION 401.1 SCOPE.
  
 2. SHEET A-4 SANITARY ISOMETRIC RISER DIAGRAM: THE
 SUBMITTED ISOMETRIC DOES NOT REFLECT THE FLOOR PLAN ON
 SHEET A-1. THE LAVATORIES, TUB, AND SHOWER ARE BEING
 INDICATED IN THE WRONG LOCATIONS. PLEASE PROVIDE A FLAT
 FLOOR PLAN DRAWING OF THE UNDERGROUND SANITARY PLUMBING
 AND CORRELATE THE RESUBMITTED SANITARY PLUMBING
 ISOMETRIC ACCORDINGLY. PER FBC-2004 PLUMBING SECTION
 701.1 SCOPE.
  
 3. SHEET A-4 SANITARY ISOMETRIC RISER DIAGRAM:
 CLEANOUTS ARE REQUIRED AT THE BASE OF THE LAVATORY
 WASTE STACKS AND CLEARLY INDICATE THE CLEANOUT AT THE
 JUNCTION OF THE BUILDING DRAIN AND BUILDING SEWER AS
 BEING A TWO-WAY CLEANOUT. PER FBC-2004 PLUMBING SECTION
 708.3.4 BASE OF STACK AND SECTION 708.3.5 BUILDING
 DRAIN AND BUILDING SEWER JUNCTION.
  
 4. SHEET A-1 FLOOR PLAN AND A-4 ELECTRICAL PLAN ARE
 INDICATING THE FOLLOWING "ADD NEW SHOWER HEAD W/
 CONTROLS". PLEASE CLARIFY IF THIS IS AN OUTSIDE SHOWER.
 IF THIS IS AN OUTSIDE SHOWER WHY IS IT NOT BEING
 INDICATED ON THE ELEVATION DRAWINGS ON SHEET A-1. IF
 THIS IS AN OUTSIDE SHOWER CLEARLY INDICATE WHERE IT IS
 GOING TO DRAIN (SUCH AS A GRASSY AREA). PER FBC-2004
 PLUMBING SECTION 417.
  
 5. NOTE: ALL PLANS, SPECIFICATIONS, AND ACCOMPANYING
 DATA BEING FILED FOR PUBLIC RECORD SHALL CONTAIN THE
 PRINTED NAME OF THE RESPONSIBLE PERSON WITH THE
 ORIGINAL SIGNATURE AND DATE ON SUCH INFORMATION. PER
 SECTION *106.3.4.3.
 IF THE DESIGN PROFESSIONAL IS AN ARCHITECT OR
 ENGINEER, THEN HE OR SHE SHALL AFFIX HIS OR HER
 OFFICIAL SEAL, SIGNATURE AND DATE TO SAID DRAWINGS, PER
 FLORIDA STATUTES 481 AND 471 RESPECTIVELY.
 (SHEET A-4 HAS NO ONE TAKING RESPONSIBILITY FOR IT)
  
 ********IMPORTANT INFORMATION********
 WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE
 OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW
 PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 END OF COMMENTS:
  