2008-08-05 09:41:24 | PLUMBING PLAN REVIEW: |
| DENIED: |
| |
| PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH |
| 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO |
| CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE |
| (F.A.C.), AND FLORIDA STATUTES (F.S.). |
| |
| THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR |
| PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE. |
| |
| 1. SHEET A-1 FLOOR PLAN: CLEARLY IDENTIFY ALL PLUMBING |
| FIXTURES ON THE FLOOR PLAN. PER FBC-20004 PLUMBING |
| SECTION 401.1 SCOPE. |
| |
| 2. SHEET A-4 SANITARY ISOMETRIC RISER DIAGRAM: THE |
| SUBMITTED ISOMETRIC DOES NOT REFLECT THE FLOOR PLAN ON |
| SHEET A-1. THE LAVATORIES, TUB, AND SHOWER ARE BEING |
| INDICATED IN THE WRONG LOCATIONS. PLEASE PROVIDE A FLAT |
| FLOOR PLAN DRAWING OF THE UNDERGROUND SANITARY PLUMBING |
| AND CORRELATE THE RESUBMITTED SANITARY PLUMBING |
| ISOMETRIC ACCORDINGLY. PER FBC-2004 PLUMBING SECTION |
| 701.1 SCOPE. |
| |
| 3. SHEET A-4 SANITARY ISOMETRIC RISER DIAGRAM: |
| CLEANOUTS ARE REQUIRED AT THE BASE OF THE LAVATORY |
| WASTE STACKS AND CLEARLY INDICATE THE CLEANOUT AT THE |
| JUNCTION OF THE BUILDING DRAIN AND BUILDING SEWER AS |
| BEING A TWO-WAY CLEANOUT. PER FBC-2004 PLUMBING SECTION |
| 708.3.4 BASE OF STACK AND SECTION 708.3.5 BUILDING |
| DRAIN AND BUILDING SEWER JUNCTION. |
| |
| 4. SHEET A-1 FLOOR PLAN AND A-4 ELECTRICAL PLAN ARE |
| INDICATING THE FOLLOWING "ADD NEW SHOWER HEAD W/ |
| CONTROLS". PLEASE CLARIFY IF THIS IS AN OUTSIDE SHOWER. |
| IF THIS IS AN OUTSIDE SHOWER WHY IS IT NOT BEING |
| INDICATED ON THE ELEVATION DRAWINGS ON SHEET A-1. IF |
| THIS IS AN OUTSIDE SHOWER CLEARLY INDICATE WHERE IT IS |
| GOING TO DRAIN (SUCH AS A GRASSY AREA). PER FBC-2004 |
| PLUMBING SECTION 417. |
| |
| 5. NOTE: ALL PLANS, SPECIFICATIONS, AND ACCOMPANYING |
| DATA BEING FILED FOR PUBLIC RECORD SHALL CONTAIN THE |
| PRINTED NAME OF THE RESPONSIBLE PERSON WITH THE |
| ORIGINAL SIGNATURE AND DATE ON SUCH INFORMATION. PER |
| SECTION *106.3.4.3. |
| IF THE DESIGN PROFESSIONAL IS AN ARCHITECT OR |
| ENGINEER, THEN HE OR SHE SHALL AFFIX HIS OR HER |
| OFFICIAL SEAL, SIGNATURE AND DATE TO SAID DRAWINGS, PER |
| FLORIDA STATUTES 481 AND 471 RESPECTIVELY. |
| (SHEET A-4 HAS NO ONE TAKING RESPONSIBILITY FOR IT) |
| |
| ********IMPORTANT INFORMATION******** |
| WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE |
| OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW |
| PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A |
| TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT |
| NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, |
| IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. |
| THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| |
| END OF COMMENTS: |
| |