Plan Review Notes For Permit 08070486 |
Permit Number |
08070486 |
|
Review Stop |
B |
Sequence Number |
2 |
|
Notes |
Date |
Text |
2008-07-21 14:49:27 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | FAC FLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | 1.SEE PREVIOUS LIST.THE PRESSURE FOR THE SYSTEM IS | | TOO LOW FOR EXPOSURE C.IF THIS BUILDING IS ADJACENT | | TO THE PARKING LOT, IT APPEARS FROM THE AERIAL THAT IT | | HAS OVER 600 FEET OF OPEN SPACE.SEE FBC1609.6.2.1(2), | | FBC1609.6.2.1(4); -114.81PSF REQUIRED FOR ZONE 3.THE | | SYSTEM SUBMITTED HAS A LIMITATION OF -90PSF. |
|