Plan Review Notes
Plan Review Notes For Permit 08070272
Permit Number 08070272
Review Stop B
Sequence Number 1
Notes
Date Text
2008-07-24 11:35:27RESIDENTIAL(R3)ADDITION, BUILDING REVIEW
 CHECKLIST.
 REVIEW UNDER FBC 2004 WITH 2007 REVISIONS.
  
 1-A) PROPERTY IS LOCATED ON FLOOD ZONE A5WITH BASE
 FLOOD ELEVATION OF 7'. IF EXISTING HOUSE AND
 PROPOSED ADDITION FINISH FLOOR ELEVATION IS LESS THAN
 7'-6", THEN THE HOUSE NEEDS TO BE RAISED AS REQUIRED BY
 CITY ORDINANCESEC. 94-546(A) AND (B).PROVIDE
 SURVEY OR ANY OTHERDOCUMENT SHOWING EXISTING FINISH
 FLOOR ELEVATION TO VERIFY COMPLIANCE WITH THIS CODE
 ORDINANCE.
  
 B) PROPOSED PLANS NEED TO SHOW THE PROPOSED FINISH
 FLOOR ELEVATION TO SHOW COMPLIANCE WITH THIS CITY
 ORDINANCE.
  
 2- SHEET #1:
 A) SPECIFYATTIC LIVE LOAD AS REQUIRED BY TABLE
 R301.5 OF 2004 FLORIDA RESIDENTIAL CODE.
 ***NOTE: COORDINATELOADS WITH TRUSS ENGINEER. SEE
 TRUSS PACKAGE.EG: PROJECT NOTES CALL FOR 30PSF ROOF
 LIVE LOAD. COORDINATE AND REVISE AS REQUIRED.
  
 B) ENTRY PORCH FOUNDATION PLAN: SPECIFY HOW MUCH
 EMBEDMENT IS REQUIRED FOR ANCHOR BOLTSAT BASE OF
 STEEL COLUMN. SEC.106.1.2 CITY AMENDMENTS TO FBC 2004
 TO VERIFY COMPLIANCE WITH UPLIFT LOADS SEC. R301 2004
 FLORIDA RESIDENTIAL CODE.
  
 C) REVISE LEVEL ALTERATION TYPE SHOWN ON PROJECT
 NOTES. SEECHAPTER 3 OF THE EXISTING BUILDING CODE
 2004TO VIEW SCOPE OF WORK AND REVISE AS REQUIRED.
  
 3- SHEET #2:
 A) PROVIDE ATTIC ACCESSFOR NEW ADDITION AS
 REQUIRED BY SEC. R807 OF 2004 FLORIDA RESIDENTIAL
 CODE.
  
 B) SPECIFY SIZE OF NEW ATTIC ACCESSWITH DROP
 LADDER TO VERIFY COMPLIANCE WITH SEC. R807.
  
 4- SHEET#3, TYPICAL WALL SECTION:
 A)REVISE ROOF SHEATHING FASTENING OPTION FOR ROOF
 ZONE #3 AS REQUIRED BY SEC. R803.2.3.1 OF 2004 FLORIDA
 RESIDENTIAL CODE.
  
 B) SPECIFY FIREBLOCKING AS REQUIRED BY SEC. R602.1.2
 OF 2004 FLORIDA RESIDENTIAL CODE.
  
 C) CLEARLY SPECIFY ROOF TILE FASTENING AS REQUIRED
 BY SEC. 106.1.1.2 CITY AMENDMENTS TO FBC 2004. ***NOTE:
 COORDINATE WITH PRODUCT APPROVAL SUBMITTED. SEE SHEET
 12 OF NOA 07-1129.04 SUBMITTED AND REVISE INFORMATION
 ON WALL SECTION AS REQUIRED.
  
 D) INDICATE LINE OF GRADE TO VERIFY COMPLIANCE WITH
 FOOTING MINIMUM DEPTH SEC. R403.1.4 OF 2004 FLORIDA
 RESIDENTIAL CODE.
  
 5- SHEET #4: SPECIFY SIZE OF STEEL CORNER BUCKET FOR
 STEEL COLUMNS.
  
 6- OWES #5.90 FOR RADON FEES.
  
 7- NEED RECORDED NOTICE OF COMMENCEMENT AS REQUIRED BY
 SEC. 713.13 FLORIDA STATUTE.
 *** NOTE: THIS MAY BE PROVIDED AT TIME OF PERMIT PICK
 UP.
  
 8- PROVIDE ENERGY CALCULATIONS AS REQUIRED BYSEC.
 13-101.2 FBC 2004.
 NOTE: MAKE SURE CORRECT REVISED FORM IS USED TO AVOID
 DELAYS OR CONFLICTS.
  
 9- SOIL TEST REPORT SUBMITTED:
 A) NEEDS TO HAVE ENGINEER'S ORIGINAL SIGNATURE (NO
 COPY) AS REQUIRED BY SEC. 61G15-23.002 (1) OF FLORIDA
 ADMINISTRATIVE CODE AND CHAPTER 471 FLORIDA STATUTE.
  
 B) NEEDS TO HAVE THE ENGINEERING FIRM CERTIFICATE OF
 AUTHORIZATION NUMBER AS REQUIRED BY SEC.
 61G15-23.002(2). FLORIDA ADMINISTRATIVE CODE.
  
 10- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9B-72 FOR:
 A) WINDOW MULLIONS.AND CLEARLY MARKSPECIFIC
 MULLION SIZE AND FASTENERS TO BE USED TO VERIFY
 COMPLIANCE WITH THE CALCULATED DESIGN PRESSURES OF SEC.
 R301.
  
 B) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON
 PLANS AND DETAILS.
 NOTE: PROVIDE ONLY THE FLORIDA PRODUCT APPROVAL COVER
 PAGE AND PAGE WHERE CONNECTOR IS LOCATED. NO NEED TO
 SUBMIT COMPLETE PRODUCT APPROVAL REPORT.
  
 11- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCTAPPROVALS AS
 REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004.
 NOTE: SEPARATE LETTER SUBMITTED BY THE ENGINEER IS
 INCOMPLETE. IT'SNO LISTING ALL PRODUCT APPROVALS AND
 IS NOT LISTING THE SPECIFIC FLORIDAPRODUCT APPROVAL
 OR NOANUMBER REVIEWED.
  
 12- TRUSS PACKAGE:
 A) INDEX SHEET DOESN'TCOMPLY WITH THE REQUIREMENTS
 OF SEC. 61G15-31.003.THE NAME OF THE ENGINEER OF
 RECORD IS NOT SHOWN AND ALL INDIVIDUAL TRUSSES NEED TO
 HAVE THE TRUSS ENGINEER NAME AND INFORMATION. REVISE AS
 REQUIRED.
  
 B) TRUSS PACKAGE NEEDS TO BE REVIEWED BY THE
 ENGINEER OF RECORD PRIOR TO SUBMITTAL TO THIS OFFICE.
  
 C) PROVIDE ONLY 2 COMPLETE COPIES WITH ORIGINAL SEAL
 AND SIGNATURE.(FOUR COPIES WHERE SUBMITTED AND TWO OF
 THOSE HAD NO ORIGINAL SIGNATURE).
  
  
 ***NOTE: PLEASE RESUBMIT PAGES WITH PALM BEACH COUNTY
 IMPACT FEES STAMP.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712