2008-07-14 12:21:55 | BUILDING PLAN REVIEW |
| PERMIT: 08060669 |
| ADD: 400 N. FLAGLER DR. #605 |
| CONT: HAWKES & DANIEL CONSTRUCTION |
| TEL: (561)315-2525 |
| FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| W/ 2007 FBC REVISIONS |
| * WEST PALM BEACH AMENDMENTS |
| |
| REVIEW: 1ST |
| ACTION: DENIED |
| |
| 1)WHEN RESUBMITTING PLANS PLEASE INDICATE THE |
| REVISION & REMOVE & REPLACE ANY PAGES AS NECESSARY. A |
| TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT |
| NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, |
| IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE |
| CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. |
| THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| |
| 2)FL S S 713.13 NOTICE OF COMMENCEMENT, TO BE FILED |
| WITH THE CLERK OF THE COURT. NOTE: 713.13(2) IF THE |
| WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT |
| ACTUALLY COMMENCED WITHIN 90 DAYS AFTER THE RECORDING |
| THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) |
| THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE |
| CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. |
| |
| 3)PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) |
| AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC |
| BUILDING WITH THE 2007 SUPPLEMENTS. |
| |
| 4)2004 FBC EXISTING 301.5 A DESIGN PROFESSIONAL OR AN |
| OWNER MUST ELECT ONE OR A COMBINATION OF LEVELS OF |
| ALTERATION PURSUANT TO SECTIONS 303, 304 AND 305 OF |
| THIS CODE. |
| |
| 5)PROVIDE DETAILED ARCHITECTURAL DRAWINGS TO CLEARLY |
| SHOW THE WORK. WILL BE SOFFIT BE INSTALLED THROUGHOUT |
| THE SPACE?SUBMIT THE FRAMING DETAILS FOR THE NEW |
| WALLS AND SOFFITS SHOWING THE STRUCTURAL ATTACHMENTS |
| AND ALL MATERIALS. |
| |
| 6)THE DRAWINGS SHALL BE SIGN AND DATED BY THE PERSON |
| TAKING RESPONSIBILITY. IF THE DESIGN PROFESSIONAL IS |
| AND ARCHITECT OR ENGINEER LEGALLY REGISTERED UNDER THE |
| LAWS OF THIS STATE, HE OR SHE SHALL AFFIX HIS OR HER |
| OFFICIAL SEAL, SIGNATURE AND DATE TO SAID DRAWING |
| SPECIFICATION AND ACCOMPANYING DATA AS REQUIRED BY |
| FLORIDA STATUTES 471 AND 481. FBC 106.1. |
| |
| 7)106.1.3 BUILDING PLANS SHALL BE DRAWN TO A MINIMUM |
| 1/8 INCH SCALE UPON SUBSTANTIAL PAPER, TO PROVIDE |
| CONFORMITY TO ITS RECORD RETENTION PROGRAM. |
| |
| 8)INDICATE THE OCCUPANCY OF THE BUILDING PER CHAPTER |
| 3 AND THE TYPE OF BUILDING PER CHAPTER 6 AND TABLE |
| 601. |
| |
| 9)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS |
| LOW. FOR PERMITTING PURPOSES VALUATION OF BUILDINGS AND |
| SYSTEMS SHALL BE TOTAL REPLACEMENT VALUE TO INCLUDE |
| ELECTRIC, INTERIOR FINISH, ARCHITECTURAL AND DESIGN |
| FEES, MARKETING COST, OVERHEAD AND PROFIT EXCLUDING |
| LAND. |
| |
| 10) 1207.3FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING |
| UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC OR |
| SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN IMPACT |
| INSULATION CLASS (IIC) RATING OF NOT LESS THAN 50 (45 |
| IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E |
| 492. PROVIDE INFORMATION MEETING THIS REQUIREMENT OR |
| INDICATE ON THE PLANS THE TYPE OF CORK WHICH WILL BE |
| USED UNDER THE TILES. |
| |
| MYRON JACOBS |
| BUILDING PLAN REVIEWER |
| (561)805-6726 |
| [email protected] |