Plan Review Notes For Permit 08060295 |
Permit Number |
08060295 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2008-06-30 15:39:19 | RESIDENTIAL (R3) POOL, BUILDING REVIEW CHECKLIST. | | REVIEW UNDER FBC 2004 WITH 2007 REVISIONS. | | | | 1- POOL DESIGN DOESN'T COMPLY WITHSEC. R4101.18 OF | | 2004 FLORIDA RESIDENTIAL CODE.NEED TO PROVIDE A WAY | | OF GETTING OUT OF THE POOL ON BOTH ENDS. REVISE AS | | REQUIRED. | | | | 2-NEED RECORDED NOTICE OF COMMENCEMENT. SEC. 713.13 | | FLORIDA STATUTE. THIS MAYBE PROVIDED AT TIME OF | | PERMIT PICKUP. | | | | 3- THIS IS A RESIDENTIAL SWIMMING POOL. CORRECT | | BUILDING CODE TO USE ISCHAPTER 41 OF THE 2004 FLORIDA | | RESIDENTIAL CODE.REVISE ALL NOTES AS REQUIRED TO CITE | | CORRECTCODE SECTION. | | | | 4- RESIDENTIAL SWIMMING BARRIER REQUIREMENTS: | | A) PROVIDEMANUFACTURER SPECIFICATIONS FOR BABY | | FENCE TO VERIFY COMPLIANCE WITH SEC. R4101.17.1.15 OF | | 2004 FLORIDA RESIDENTIAL CODE. | | | | B) EXISTING WOOD FENCE: PROVIDE SPECIFICATIONS FOR | | GATE TO SHOW COMPLIANCE WITH SEC. R4101.17.1.8 OF 2004 | | FLORIDA RESIDENTIAL CODE. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|