Plan Review Notes For Permit 08060149 |
Permit Number |
08060149 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2008-06-10 08:50:22 | DURING PRE-INSPECT WAS ABLE TO GET ON ROOF. NOTICED | | SEVERE CRACKING TO CAP SHEET, SPONGY UNDER FOOT | | INDICATING WATER IN PLYS. CALLED CONTRACTOR, AND WE | | AGREED THIS SHOULD BE A RE-ROOF COMPLETE TEAR OFF. HE | | WILL REVISE SCOPE OF WORK. |
|