2008-06-10 16:48:50 | ****CORRECTIONS**** |
| SAMANTHA HILL, BUILDING PLANS EXAMINER |
| 561-805-6724 [email protected] |
| FBC FLORIDA BUILDING CODE 2004 |
| FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL |
| |
| SHUTTER PERMIT APPLICATION, ONLY CHECKED ITEMS APPLY |
| |
| _XX_1.DESIGN PRESSURES FOR BUILDINGS OVER 60FEET |
| ARE REQUIRED TO BE DESIGNED USING ASCE7, FBC1609.1.1 |
| AND MUST BE DONE BY A DESIGN PROFESSIONAL. DOCUMENTS |
| PREPARED BY AN ARCHITECT OR ENGINEER AND SUBMITTED FOR |
| PUBLIC RECORD ARE TO BE SIGNED SEALED ORIGINALS |
| FAC61G15, FAC61G1 16. |
| THE ENGINEERING SPECIFIES -95.09, -84.11, BUT THE |
| INSTALLATION SCHEDULE SPECIFIES -71.9 AND -76.1. |
| PLEASE REVISE. |
| |
| _XX_2.TWO SETS OF PERMIT DOCUMENTS REQUIRED. |
| |
| ____3.COMPLETE THE ATTACHED INSTALLATION SCHEDULE |
| OR PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN |
| ANOTHER FORMAT, FBC*106.TWO SETS REQUIRED. |
| HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_ |
| INSTALLATION.PDF |
| |
| ____4.FLORIDA STATE OR LOCAL PRODUCT APPROVAL |
| REQUIRED, FAC9B72, WWW.FLORIDABUILDING.ORG. |
| |
| ____5.SHOW THE EMERGENCY MEANS OF ESCAPE, FBC |
| R310. |
| |
| ____6.PROVIDE A FLOOR PLAN SHOWING WHERE THE |
| SHUTTERS WILL BE INSTALLED AND PANEL SIZES WHICH |
| CORRELATES WITH THE INSTALLATION SCHEDULE, ITEM 3 |
| ABOVE. |
| |
| ____8.REVISE EXPOSURE CATEGORY OR EXPLAIN RATIONALE |
| FOR EXPOSURE B.NOTE THAT THE DEFINITION FOR EXPOSURE |
| C HAS CHANGED EFFECTIVE DECEMBER 8, 2006 FBC1609.4, FBC |
| R301.2.1.4. |