2008-06-10 16:48:50****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2004
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL
  
 SHUTTER PERMIT APPLICATION, ONLY CHECKED ITEMS APPLY
  
 _XX_1.DESIGN PRESSURES FOR BUILDINGS OVER 60FEET
 ARE REQUIRED TO BE DESIGNED USING ASCE7, FBC1609.1.1
 AND MUST BE DONE BY A DESIGN PROFESSIONAL. DOCUMENTS
 PREPARED BY AN ARCHITECT OR ENGINEER AND SUBMITTED FOR
 PUBLIC RECORD ARE TO BE SIGNED SEALED ORIGINALS
 FAC61G15, FAC61G1 16.
 THE ENGINEERING SPECIFIES -95.09, -84.11, BUT THE
 INSTALLATION SCHEDULE SPECIFIES -71.9 AND -76.1.
 PLEASE REVISE.
  
 _XX_2.TWO SETS OF PERMIT DOCUMENTS REQUIRED.
  
 ____3.COMPLETE THE ATTACHED INSTALLATION SCHEDULE
 OR PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN
 ANOTHER FORMAT, FBC*106.TWO SETS REQUIRED.
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_
 INSTALLATION.PDF
  
 ____4.FLORIDA STATE OR LOCAL PRODUCT APPROVAL
 REQUIRED, FAC9B72, WWW.FLORIDABUILDING.ORG.
  
 ____5.SHOW THE EMERGENCY MEANS OF ESCAPE, FBC
 R310.
  
 ____6.PROVIDE A FLOOR PLAN SHOWING WHERE THE
 SHUTTERS WILL BE INSTALLED AND PANEL SIZES WHICH
 CORRELATES WITH THE INSTALLATION SCHEDULE, ITEM 3
 ABOVE.
  
 ____8.REVISE EXPOSURE CATEGORY OR EXPLAIN RATIONALE
 FOR EXPOSURE B.NOTE THAT THE DEFINITION FOR EXPOSURE
 C HAS CHANGED EFFECTIVE DECEMBER 8, 2006 FBC1609.4, FBC
 R301.2.1.4.