Plan Review Notes For Permit 08050661
Permit Number 08050661
Review Stop P
Sequence Number 2
Notes
Date Text
2008-07-24 15:41:23****************PROVISO****************
 A} GRAB BAR BEHIND H/C WATER CLOSET SHALL BE A MINIMUM
 OF 36 INCHES (36"). PER FBC-2004 CHAPTER 11, FLORIDA
 ACCESSIBILITY CODE, SECTION 11-4.16.4.
 B} H/C LAV SHALL COMPLY WITH FIG. 31 FOR KNEE & TOE
 CLEARANCE. PER FBC-2004 CHAPTER 11, FLORIDA
 ACCESSIBILITY CODE, SECTION 11-4.19.2.
 C} WATER-HAMMER ARRESTORS SHALL BE INSTALLED IN
 ACCORDANCE WITH THE MANFACTURER'S RECOMENDATIONS. PER
 FBC-2004 PLUMBING SECTION 604.9.
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER