2008-05-21 10:45:48 | RESIDENTIAL(R3)SHUTTERS,BUILDINGREVIEW | | CHECKLIST. | | REVIEW UNDER FBC 2004 WITH 2007 REVISIONS. | | | | 1- REVISE INSTALLATION SCHEDULE ANCHOR SPACING.ANCHOR | | SPACING ON SHUTTERS PRODUCT APPROVAL PAGE 10 OF 14IS | | TO BE USED ONLY WHEN THE EDGE DISTANCE IS 3-1/2". | | INFORMATION GIVEN ON CITY'S INSTALLATION SCHEDULE SHOWS | | THE EDGE DISTANCE TO BE AT 3".ACCORDING TO PAGE 11 OF | | 14 OFSHUTTERS DRAWINGS ANCHOR SPACING NEEDSTO BE | | REDUCED AS REQUIRED BY THE EDGE DISTANCE VERSUS SPACING | | FOR ANCHORS TABLE.REVISE ANCHOR SPACING IN CITY'S | | INSTALLATION SCHEDULE AS REQUIRED. | | | | 2-NEED RECORDED NOTICE OF COMMENCEMENT AS REQUIRED BY | | SEC. 713.13 FLORIDA STATUTE. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|