2008-05-29 14:19:46 | PLUMBING PLAN REVIEW: |
| DENIED: |
| |
| PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH |
| 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO |
| CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE |
| (F.A.C.), AND FLORIDA STATUTES (F.S.). |
| |
| THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR |
| PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE. |
| |
| 1. SHEET A.01 DETAIL 1, EXISTING/DEMOLITION PLAN: |
| INDICATES ONE LAVATORY IN DRESSING AND ONE BIDET IN THE |
| MASTER BATH BEING DELETED. PLEASE ADD THE FOLLOWING TO |
| NOTES PER FBC-2004 PLUMBING, SECTION 704.5 DEAD ENDS: |
| IN THE INSTALLATION OR REMOVAL OF ANY PART OF A |
| DRAINAGE SYSTEM, DEAD ENDS SHALL BE PROHIBITED. A |
| PLUMBING PERMIT IS REQUIRED AND AN INSPECTION IS |
| REQUIRED OF PLUMBING DEMO WORK PRIOR TO COVERING DEMO |
| WORK WITH FINNISH WALLS, CIELINGS, OR POURED CONCRETE |
| SLABS. |
| |
| 2. PROVIDE A DETAIL ON HOW THE SLEEVE HOLE FOR THE |
| BIDET WILL BE SAFEGUARDED AGAINST THE SPREAD OF FIRE |
| AND SMOKE WHEN THE DRAINAGE PIPE IS REMOVED. PER |
| FBC-2004 BUILDING SECTION 701.1 SCOPE. |
| |
| 3. SHEET A.01 DETAIL 2, NEW FRAMING PLAN: CLEARLY |
| INDICATE THE SCOPE OF WORK IN THE POWDER ROOM. DEMO |
| PLAN INDICATED PLUMBING FIXTURES BEING REMOVED, HOWEVER |
| THERE IS NO INDICATION IF THE OLD PLUMBING FIXTURES ARE |
| BEING REINSTALLED OR IF NEW ONES ARE BEING INSTALLED. |
| PLEASE CLARIFY THIS ON THE RESUBMITTAL. PER (W.P.B.AS |
| AMENDED) SECTION 106.1.1 INFORMATION ON CONSTRUCTION |
| DOCUMENTS. |
| |
| 4. SHEET A.01 DETAIL 2, NEW FRAMING PLAN: CLEARLY |
| INDICATE ON THE RESUBMITTED PLANS IF A NEW KITCHEN SINK |
| OR THE OLD KITCHEN SINK IS BEING INSTALLED IN THE NEW |
| KITCHEN COUNTER TOP. PLEASE ALSO INDICATE THE KITCHEN |
| SINKS LOCATION. PER (W.P.B. AS AMENDED) SECTION 106.1.1 |
| INFORMATION ON CONSTRUCTION DOCUMENTS. |
| |
| 5. SHEET A.01 DETAIL 2, NEW FRAMING PLAN: CLEARLY |
| INDICATE THAT THE GLASS DOOR IN THE NEW IN THE GUEST |
| BATH COMPLIES WITH FBC-2004 PLUMBING SECTION 417.6 |
| GLAZING.WINDOWS AND DOORS WITHIN A SHOWER ENCLOSURE |
| SHALL CONFORM TO THE SAFETY GLAZING REQUIREMENTS OF THE |
| FLORIDA BUILDING CODE, BUILDING SECTION 2406 HAZARDOUS |
| LOCATIONS.(5) |
| |
| 6. PROVIDE A SANITARY AND POTABLE WATER ISOMETRIC |
| RISER DIAGRAM OF THE PROPOSED NEW LAVATORY BEING |
| INSTALLED IN THE MASTER BATHROOM. PER (W.P.B.AS |
| AMENDED) SECTION 106.3.5.1.3 PLUMBING |
| (3)(4)(6)(10)(13). |
| |
| ********IMPORTANT INFORMATION******** |
| WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE |
| OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW |
| PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A |
| TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT |
| NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, |
| IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. |
| THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| |
| END OF COMMENTS: |
| |
| REVIEW BY: MIKE PERSON |
| PLUMBING PLANS EXAMINER |
| PHONE= (561) 805-6730 |
| FAX= (561) 805-6731 |
| E-MAIL= [email protected] |