Plan Review Notes For Permit 08050395 |
Permit Number |
08050395 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2008-05-23 15:54:20 | 2004 FBC W/2007 REVISIONS | | LEVEL 2 ALTERATIONS | | | | DENIED BY BUILDING | | | | 1) THE NAME OF THE PERSON RESPONSIBLE FOR THE DRAWING | | IS REQUIRED ON EACH SHEET. SEE FBC 106.3.4.3* CITY | | AMENDMENTS. | | | | 2) THE FLOOR PLAN DOES NOT SPECIFY WHICH DOORS AND | | WINDOWS ARE BEING REPLACED. THE PLAN APPEARS TO SHOW | | ONE OF THE WINDOWS IN BED ROOM #2 BEING REPLACED BY A | | DOOR. PLEASE CLEARLY INDICATE THE DOORS AND WINDOWS | | THAT WILL BE REPLACED. FBC 106.1.1* CITY AMENDMENTS | | | | 3)SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR THE | | EXTERIOR DOORS. DCA RULE 9B-72 | | | | 4) THE DRYWALL SCREW SPACING INFORMATION FOR THE FIELD | | IS MISSING FROM THE BOTTOM OF THE INTERIOR WALL SECTION | | DRAWING. | | | | 5) THE EXISTING WALL SHEATHING WILL NEED TO BE | | INSPECTED BY THE BUILDING INSPECTOR AFTER THE ALUMINUM | | SIDING IS REMOVED AND BEFORE IT IS COVERED. | | | | 7) ASTM C 926 REQUIRES THE STUCCO TO BE 7/8" THICK. | | PLEASE REVISE PLAN. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|