2008-06-20 18:05:02 
  
  
 DENIED
  
 THE FOLLOWING COMMENT WERE NOT ADDRESSED IN 1ST REVIEW
  
 1)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS
 LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS
 AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST
 EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC
 (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES
 PER 108.3 FBC*
  
 2)THE STATE OF FLORIDA REQUIRES COLLECTION OF A RADON
 SURCHARGE ON ALL NEW CONSTRUCTION COMPUTED ON UNDER
 ROOF FLOOR SPACE PER 10D-91 FAC. THESE FEES WILL BE
 ADDED TO THE PERMIT APPLICATION FEES
  
 NOTE: FEES ARE DUE IN THE AMOUNT OF $851.56 FOR
 INCREASED VALUE AND STATE RADON FEES THIS AMOUNT IS
 REQUIRED TO BE PAID PRIOR TO FURTHER PLAN REVIEW
  
 5)WINDOW TYPE #4 REQUIRES 2X4 MULLION AS STATED ON
 SCHEDULE BUT NO PRODUCT APPROVAL WAS SUBMITTED.
 *********THE CHANGE THAT IS REQUIRED WAS TO ADD A
 PRODUCT APPROVAL FOR 2X4 MULLIONS TO THE SUBMITTAL ,
 PLEASE SEE THAT THE 1X4 MULLION FOR 100" OPENING WIDTH
 AND A 108" OPENING HEIGHT WILL ONLY WORK FOR A DESIGN
 PRESSURE OF 22 PSF OR LESS PER PAGE 5 OF THE MULLION
 PRODUCT APPROVAL********
  
 NEW COMMENTS
  
 1)THE PRODUCT APPROVALS FOR THE SINGLE HUNG AND FIXED
 WINDOWS WERE NOT RESUBMITTED, PERMIT APPLICATION
 PACKAGE MUST BE COMPLETE FOR FINAL STAMPING AND PERMIT
 ISSUANCE
  
 2)GLASS BLOCK PRODUCT APPROVALS ONLY MEET THE SMALL
 MISSILE IMPACT REQUIREMENTS, OPENINGS WITHIN THE FIRST
 30 FEET FROM GRADE MUST MEET LARGE MISSILE IMPACT
 CRITERIA PER 1609.1.4 FBC, THE SILICONE SET BLOCK MEETS
 THIS REQUIREMENT OR SHUTTERS WILL BE REQUIRED AND THE
 PRODUCT APPROVALS SUBMITTED
  
 3)ONLY ONE COPY OF LANDSCAPE PLAN AND SOIL REPORT
 WERE SUBMITTED
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  
  
  
  