Plan Review Notes
Plan Review Notes For Permit 08050091
Permit Number 08050091
Review Stop B
Sequence Number 1
Notes
Date Text
2008-05-10 12:44:58 
  
 DENIED
  
 1)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS
 LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS
 AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST
 EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC
 (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES
 PER 108.3 FBC*
  
 2)THE STATE OF FLORIDA REQUIRES COLLECTION OF A RADON
 SURCHARGE ON ALL NEW CONSTRUCTION COMPUTED ON UNDER
 ROOF FLOOR SPACE PER 10D-91 FAC. THESE FEES WILL BE
 ADDED TO THE PERMIT APPLICATION FEES
  
  
 NOTE: FEES ARE DUE IN THE AMOUNT OF $851.56 FOR
 INCREASED VALUE AND STATE RADON FEES THIS AMOUNT IS
 REQUIRED TO BE PAID PRIOR TO FURTHER PLAN REVIEW
  
 3)ZONING REQUIRES A LANDSCAPE PLAN, PLEASE ADD A
 DRAINAGE PLAN PER R401.3 FBC RES. THAT SHOWS DRAINAGE
 AWAY FROM BUILDING AND PROPERTY LINES
  
 4)WINDOW #6 IN WINDOW SCHEDULE HAS H36 AS 53 1/8"
 WIDE THIS WINDOW IS 26 1/2" WIDE AND ALSO DOES NOT MEET
 EGRESS REQUIREMENTS WITH ONLY 4.93 SQ. FT. CLEAR
 OPENING AREA. SGD WILL MEET THE EGRESS REQUIREMENTS FOR
 THIS ROOM.
  
 5)WINDOW TYPE #4 REQUIRES 2X4 MULLION AS STATED ON
 SCHEDULE BUT NO PRODUCT APPROVAL WAS SUBMITTED.
  
 6)CLARIFY TOP OF BEAM ELEVATION FOR FOYER AND FRONT
 PORCH, ROOF PLAN ON A-5.0 SHOWS 9'-4" BUT CEILING
 ELEVATION IS 14'-4" AS IS DETAIL 5 ON D-1
  
 7)PROVIDE MIN ROOF SHEATHING ATTACHMENT PER
 R803.2.3.1 FBC RES. MINIMUM 8D RING SHANK NAILS
  
 8)SUBMIT ENGINEERED TRUSS DRAWINGS THAT COMPLY WITH
 R802.10.1 FBC WITH PERMIT APPLICATION OR BEFORE
 INSTALLATION THAT HAVE BEEN REVIEWED AND APPROVED BY
 THE DESIGNER OF RECORD
  
 9)PROVIDE GLASS TYPE FOR SLIDING GLASS DOORS WITH
 PANELS 48" IN WIDTH (DOOR "T" AND "U"), PLEASE NOTE
 THAT TYPE "A" (MIN) GLASS WILL MEET DESIGN PRESSURES
 FOR ALL THE PANEL SIZES BELOW 48" BUT DO NOT MEET THE
 REQUIRED PRESSURE FOR THE LARGER PANELS
  
 10)PLEASE NOTE THAT A GAS PERMIT WILL BE REQUIRED,
 SEE ATTACHED INFORMATION NEEDED FOR GAS PERMIT
  
 11)APPROACH PERMIT WILL BE REQUIRED PLEASE NOTE THAT
 NO CONTRACTOR HAS SIGNED ON TO PERMIT AND NO PERMIT
 NUMBER HAS BEEN GENERATED, APPROCH PERMITS REQUIRE
 ENGINEERING REVIEW
  
 REMOVE ALL OLD PAGES AND RESUBMIT 2 COMPLETE SETS OF
 NEW DRAWINGS WITH REVISIONS AND INCLUDE 1 COPY OF THE
 OLD PAGES ONLY FOR REFERENCE. PLEASE RE-SUBMIT ANY
 PAGES WITH THE IMPACT FEE STAMP. ALL OUT DATED OR NON
 REQUIRED PRODUCT APPROVALS CAN BE REMOVED
  