2008-07-07 08:06:12DENIED
 REFERENCE: FBC-2004 PLUMBING
 FBC-2004 CHAPTER 1
 FBC-2004 CHAPTER 11
 FBC-2004 BUILDING
  
 ****FROM PREVIOUS REVIEW:
  
 1. OK
 2. OK
 3. OK
 4. OK
 5. OK
 6. OK
 7. OK
  
 8. SUBMIT DETAILS AND ELEVATIONS FOR THE TOILET ROOM
 AND THE BATHROOM SHOWING COMPLIANCE WITH SECTIONS
 11-4.16, 11-4.19, 11-4.21, 11-4.22 & 11-4.23 WITH ALL
 SUBSECTIONS AND FIGURES. INDICATE THE SIZE OF THE
 SHOWER. SEE SECTION 11-4.21.2 & FIG 35(A). ****RESPONSE
 NOTED, BUT SHOW COMPLIANCE FOR THE FOLLOWING:
 __FOR W/C'S:
 A. 11-4.16.5 FLUSH CONTROLS (TO THE WIDE SIDE) __FOR
 LAVS"
 A. 11-4.19.2 CLEARANCE (29" MIN. NOT MAX.)
 __FOR SHOWERS:
 A. 11-4.21.3 SEAT (HEIGHT)
 B. 11-4.21.5 CONTROLS
 C. 11-4.21.6 SHOWER UNIT
 D. 11-4.21.7 CURBS (1/2" MAX)
  
 9. OK
 10. OK
 11. OK
 12. OK
  
 13. SHT A7.1.1 ROOM FINISH SCHEDULE FOR ROOM 246. SHOW
 COMPLIANCE WITH SECTION 1210.1 REQUIREMENT FOR FLOORS
 TO HAVE A SMOOTH, HARD, NONABSORBENT SURFACE. CARPET
 DOES NOT COMPLY WITH THESE REQUIREMENT. PLEASE SHOW
 COMPLIANCE.
 ****RESPONSE NOTED, BUT NOT INDICATED ON THE FINISH
 SCHEDULE.
  
 14. OK
 15. OK
 16. OK
  
 17. SUBMIT AN ISOMETRIC WATER RISER DIAGRAM FOR THE
 BREAK ROOM SINK, DRINKING FOUNTAINS, DISHWASHER ETC
 SHOWING ALL PIPE SIZES, VALVES AND , WHERE REQUIRED,
 WATER HAMMER ARRESTORS PER 604.9, (ANY ICE MAKERS,
 DISHWASHERS ETC), INSTALLED NEAR THE FIXTURES IN AN
 "EFFECTIVE RANGE" NOT IN THE CEILING. SECTIONS
 106.3.5.1.3, 601.1, 604 - TABLE 604.5 & PDI-WH 201.
 ****RESPONSE NOTED, BUT WATER HAMMER ARRESTOR IS
 REQUIRED AT THE DISHWASHER BUT NOT SHOWN.
  
 18. OK
 19. OK
 20. OK
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE, IDENTIFYING
 THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731