Plan Review Notes
Plan Review Notes For Permit 08040092
Permit Number 08040092
Review Stop Z
Sequence Number 1
Notes
Date Text
2008-04-04 13:33:31***FAILED***
  
  
 1)PROPOSED FENCE ENCROACHES INTO THE REQUIRED
 VISIBILITY TRIANGLE.PURSUANT TO SECTION 94-305(E) OF
 THE CITY'S ZONING AND LAND DEVELOPMENT REGULATIONS:
  
 VISIBILITY AT INTERSECTIONS.AT ANY ROAD
 INTERSECTIONS, VISIBILITY SHALL NOT BE OBSCURED BY THE
 CONSTRUCTION, PLACEMENT, OR MAINTENANCE OF A STRUCTURE
 WALL, SIGN, FENCE, BERM, PLANT MATERIAL, SHRUBS, OR ANY
 SIMILAR ITEM BETWEEN 18 INCHES OR EIGHT FEET IN HEIGHT
 WITHIN A TRIANGLE BEGINNING AT THE POINT WHERE PROPERTY
 LINES MEET AT THE CORNER, THEN 20 FEET ALONG THE FRONT
 PROPERTY LINE, THENCE DIAGONALLY TO A POINT ALONG THE
 SIDE PROPERTY LINE 20 FEET FROM THE POINT OF BEGINNING,
 AND THENCE TO THE POINT OF BEGINNING. IN THE EVENT THE
 CORNER OF AN INTERSECTION IS ROUNDED, THE MEASUREMENT
 SHALL BEGIN AT THE POINT THE PROPERTY LINES WOULD MEET
 WITHOUT ROUNDING. (SEE FIGURE X-1 ATTACHED WITH PERMIT
 APPLICATION PACKET).
  
 2)PROPOSED FENCE IS SHOWN ON TOP OF AN EXISTING
 C.B.S. WALL.PROVIDE AN ELEVATION SHOWING THE HEIGHT
 OF THE EXISTING WALL AND THE TOTAL HEIGHT WITH THE
 PROPOSED FENCE (SHOWN FROM THE SIDEWALK LEVEL).
  
 THE TOTAL HEIGHT OF THE WALL/FENCE MAY NOT EXCEED 4
 FEET FROM THE SIDEWALK LEVEL WITHIN THE REQUIRED FRONT
 SETBACK (ALONG 20TH STREET AND 20 FEET BACK FROM THAT
 PROPERTY LINE).ADDITIONALLY, THE WALL/FENCE MAY NOT
 EXCEED 6 FEET IN TOTAL HEIGHT WITHIN THE SIDE SETBACK
 (ALONG DIVISION STREET).
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS,
 ZONING TECHNICIAN (561)805-6720