2008-04-14 15:11:44****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 1.THE ENGINEERING WAS REMOVED FROM THE PERMIT
 PACKAGE.ENGINEERING IS REQUIRED FOR BUILDINGS OVER
 60FEET USING ASCE7-02, SEE FBC1609.YOU ARE PROPOSING
 TO USE A SYSTEM WITH A LIMITATION OF -120, BUT FBC
 TABLE 1609.6.2.1(2) AND (4) WOULD REQUIRE A DESIGN
 PRESSURE OF -144 FOR 60FEET, EXPOSURE C.THIS IS A 22
 STORY BUIDLING.PLEASE PROVIDE ENGINEERING AND SELECT
 A SYSTEM WHICH COMPLIES WITH THE PRESSURES SPECIFIED BY
 THE ENGINEER.