 BUILDING PLAN REVIEW
 PERMIT: 08030674
 ADD: 2000 PRESIDENTIAL WAY #1201
 CONT: CATEGORY 5 HURRICANE SHUTTERS
 TEL: (561)620-9152
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW: 1ST 4-2-08
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 2)THE DESIGN PRESSURES SUBMITTED SEEMS LOW FOR THE
 HEIGHT OF THE BUILDING. WHEN USING THE DESIGN PRESSURES
 FROM TABLE 1609.6.2.1(2) AND TABLE 1609.6.2.1(4) FOR
 EXPOSURE {C} FOR BUILDINGS 60 FEET IN HEIGHT, THE
 DESIGN PRESSURES ARE FAIRLY CLOSE TO THE PRESSURES
 SUBMITTED FOR A BUILDING WITH A MEAN ROOF HEIGHT OF 188
 FEET. ON THE CALCULATION SHEET, STATE WHAT METHOD IS
 BEING USED TO ACHIEVE THE DESIGN PRESSURES.
  
 3)FBC 1609.1.1
 WIND LOADS ON EVERY BUILDING OR STRUCTURE SHALL BE
 DETERMINED IN ACCORDANCE WITH SECTION 6 OF ASCE 7. WIND
 SHALL BE ASSUMED TO COME FROM ANY HORIZONTAL DIRECTION
 AND WIND PRESSURES SHALL BE ASSUMED TO ACT NORMAL TO
 THE SURFACE CONSIDERED. THE ENGINEER SHALL STATE
 HIS/HER DESIGN CRITERIA ON EACH CALCULATION SHEETS. THE
 SHEETS SUBMITTED DOES NOT STATE THIS INFORMATION.
  