Plan Review Notes
Plan Review Notes For Permit 08030517
Permit Number 08030517
Review Stop P
Sequence Number 1
Notes
Date Text
2008-08-28 09:48:26PLUMBING PLAN REVIEW:
 DENIED:
  
 PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH
 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO
 CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.), AND FLORIDA STATUTES (F.S.).
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE.
  
 1. SHEET A1 SCOPE OF WORK: THE SCOPE OF WORK IS NOT
 CLEAR DUE TO A SUBMITTED SANITARY ISOMETRIC RISER
 DIAGRAM BEING INDICATED ON SHEET A2. PLEASE CLARIFY IF
 IT IS THE INTENT TO REPLACE THE SANITARY SYSTEM WITH
 NEW PIPE IN THE SCOPE OF WORK. PLEASE KNOW THAT A
 PLUMBING PERMIT WILL BE REQUIRED IF THAT IS THE INTENT.
 PER (W.P.B. AS AMENDED) SECTION 106.1.1 INFORMATION ON
 CONSTRUCTION DOCUMENTS.
  
 2. SHEET A2 SANITARY PLUMBING RISER: PLEASE CORRECT
 THE FOLLOWING PER THE FBC-2004 PLUMBING SECTIONS.
  
 A} THE RISER DIAGRAM DOES NOT RELECT THE FLOOR PLAN.
 THE KITCHEN SINK BEING INDICATED ON SHEET A1 HAS TWO
 BOWLS. CLEARLY INDICATE THIS ON THE RESUBMITTAL. PER
 SECTION 701.1 SCOPE.
  
 B} SIZE ALL WASTE PIPING AND WATER-SEAL TRAPS. PER
 SECTION 701.1 SCOPE.
  
 C} HORIZONTAL WASTE PIPING AND STACK FOR THE WASHING
 MACHINE SHALL BE 3 INCH AND THE WASHING MACHINE
 WATER-SEAL TRAP SHALL BE 2 INCH. PER SECTION 406.3
 WASTE CONNECTIONS.
  
 D} A 3 INCH CLEANOUT FOR THE WASHING MACHINE STACK IS
 REQUIRED AND IT SHALL BE LOCATED AT FOUR FEET ABOVE
 FINNISH FLOOR (4" A.F.F.) PER SECTION 708.9 ACCESS.
  
 E} PER THE LOCATION OF THE WASTE STACK FOR THE KITCHEN
 SINK A 2 INCH WASTE ARM IS REQUIRED FOR THE KITCHEN
 SINK. PER TABLE 906.1 MAXIMUM DISTANCE OF FIXTURE TRAP
 FROM VENT.
 NOTE: WITH HAVING TO INSTALL A 2 INCH WASTE ARM FOR
 THE KITCHEN SINK PLEASE KNOW THAT THE STRUCTURAL
 INTEGRITY OF THE EXTERIOR WALL IS AFFECTED AND THE WALL
 WILL NEED TO BE INSTALLED PER FBC-2004 RESIDENTIAL
 SECTION R602.2.7 DRILLING AND NOTCHING-STUDS.
  
 F} THE LAVATORY WATER-SEAL TRAP CAN BE EITHER 1-1/4
 INCH OR 1-1/2 INCH. PLEASE KNOW THAT IF ITS SIZED 1-1/4
 INCH A CLEANOUT SHALL BE REQUIRED AT THE BASE OF ITS
 WASTE STACK. PER SECTION 708.7 MINIMUM SIZE, EXCEPTIONS
 (1), AND SECTION 708.3.5 BASE OF STACK.
  
 ********IMPORTANT INFORMATION********
 WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE
 OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW
 PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 PHONE= (561) 805-6730
 FAX= (561) 805-6731
 E-MAIL= [email protected]