Plan Review Notes For Permit 08020629 |
Permit Number |
08020629 |
|
Review Stop |
B |
Sequence Number |
2 |
|
Notes |
Date |
Text |
2008-08-18 10:05:27 | 2004FBC W/2007 REVISIONS | | LEVEL 2 ALTERATION AND ADDITION | | | | DENIED BY BUILDING | | | | 1) THE NOTICE OF COMMENCEMENT IS REQUIRED TO BE | | RECORDED AT THE COUNTY COURTHOUSE. A COPY OF THE | | RECORDED NOC WILL BE REQUIRED. FS 713 | | | | 2) SUBMIT A KEY PLAN INDICATING THE LOCATIONS OF THE | | OPENINGS LISTED ON THE STORM PANEL SCHEDULE. THE STORM | | PANEL SCHEDULE IS INCORRECTAND INCOMPLETE. THE | | CONNECTION TYPES ARE C1,C2,C3,C4 AND C5. FOR MINIMUM | | GLASS SEPARATION SEE TABLE 2 ON SHEET 4 OF THE PRODUCT | | APPROVAL NOA. IF THE HEIGHT OF THE WINDOW IS 52"AND | | THE PANELS ARE INSTALLED VERTICAL THE SPAN IS 56" NOT | | 37".SPECIFY THE TOP AND BOTTOM ANCHOR SPACING. | | SPECIFY THE SUBSTRATE TO WHICH THE ANCHORS WILL BE | | ATTACHED. | | FBC R301.2.1.2 | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|