2008-02-27 14:16:12 | 2004 FBC W/2007 REVISIONS |
| LEVEL 3 ALTERATIONS AND ADDITION |
| EXPIRED PERMIT 05070071 |
| |
| DENIED BY BUILDING |
| |
| 1)A RECORDED COPY OF THE NOTICE OF |
| COMMENCEMENT WILL BE REQUIRED. |
| |
| 2) IMPACT FEES MUST BE PAID TO PALM |
| BEACH COUNTY, PLANS STAMPED BY THEM AND |
| COPY OF RECEIPT SUBMITTED TO CITY OF |
| WEST PALM BEACH BUILDING DEPARTMENT, |
| BEFORE A BUILDING PERMIT CAN BE ISSUED. |
| |
| 3) THE PLANS ARE REQUIRED TO HAVE THE RAISED SEAL AND |
| ORIGINAL SIGNATURE OF THE ARCHITECT. COPIED SIGNATURES |
| ARE NOT ALLOWED. FS 481 |
| |
| 4) THE SITE PLAN INDICATES THAT ONE WALL OF THE |
| ADDITION IS 5' FROM THE PROPERTY LINE. SUBMIT A SITE |
| PLAN OR SURVEY THAT SHOWS THAT THE DISTANCE TO THE |
| STRUCTURES ON THE ADJACENT PROPERTY IS MORE THAN 6 FEET |
| OR SHOW COMPLIANCE WITH FBC R302.1 AND R302.2 WHICH |
| REQUIRE ONE HOUR FIRE RATED WALLS AND NO OPENINGS IN |
| WALLS WITH LESS THAN 6 FEET OF SEPARATION. |
| |
| 5) SUBMIT TWO (2) COPIES OF CURRENT (2004 FBC) PRODUCT |
| APPROVALS FOR THE NEW EXTERIOR DOORS, WINDOWS, WINDOW |
| MULLIONS, ROOF COVERING, WOOD CONNECTORS AND STORM |
| PANELS. FAC RULE 9B-72. |
| |
| 6)FBC 106.3* CITY AMENDMENTS PRODUCT APPROVALS. |
| THOSE PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 |
| SHALL BE REVIEWED AND APPROVED IN WRITING BY THE |
| DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR |
| JURISDICTIONAL APPROVAL. |
| |
| 7) SUBMIT TWO COPIES OF A KEY PLAN AND INSTALLATION |
| SCHEDULE FOR THE STORM PANELS. SPECIFY THE MOUNT TYPE, |
| ANCHOR TYPE AND SPACING, EDGE DISTANCE, ETC. SEE |
| ATTACHED SAMPLE OF INSTALLATION SCHEDULE. FBC 106.1.1* |
| CITY AMENDMENTS. |
| |
| 8) SPECIFY THE WINDOW TYPES AND SIZES ON THE PLANS. FBC |
| 106.1.1*CITY AMENDMENTS. |
| |
| 9)SUBMIT TWO COPIES OF ENERGY CALCULATIONS FOR THE |
| ADDITION AS REQUIRED BY FBC 11-600. NOTE: OWNER/AGENT |
| IS REQUIRED TO SIGN THE ENERGY CALC. FORMS. |
| |
| 10) PROVIDE BUCK DETAILS FOR THE WINDOWS AND DOORS. SEE |
| FBC 1714.5.4.2 |
| |