Plan Review Notes For Permit 08020013 |
Permit Number |
08020013 |
|
Review Stop |
B |
Sequence Number |
2 |
|
Notes |
Date |
Text |
2008-02-19 10:55:35 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | FAC FLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | | | 1.PLEASE REMOVE DOCUMENTS WHICH ARE NOT A PART OF THE | | PRODUCT APPROVAL.THIS REVIEW HAS BEEN DONE BASED ON | | THE MIAMIDADE NOA PROVIDED AS I CANNOT DETERMINE WHERE | | THE CUT SHEETS CAME FROM.WHEN I GO TO THE FLORIDA | | PRODUCT APPROVAL SITE, WWW.FLORIDABUILDING.ORG, IT | | APPEARS THAT MIAMIDADE NOAS WERE SUBMITTED.THEREFORE, | | COMPLIANCE WITH THIS PRODUCT APPROVAL IS REQUIRED | | UNLESS OTHER PAPERWORK IS SUBMITTED.AS DISCUSSED, THE | | INSTALLATION SCHEDULE SPECIFIES 2" GLASS SEPARATION; 2 | | 7/8 REQUIRED (SHEET SSHB C 050B). | | | | 2.DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED FOR | | PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | ORIGINALS.THE ENGINEERING SUBMITTED ADDRESSED ONLY | | ANCHORING INTO THE EXISTING GLASS DOOR FRAME.NOTE | | THAT GLASS SEPARATION ALSO NEEDS TO BE ADDRESSED. | | | | |
|