Date |
Text |
2008-02-12 16:16:37 | |
| PROJECT: 249 ASHWORTH ROAD/#08010647 |
| |
| CODE REVIEW: |
| 2004 FLORIDA EXISTING BUILDING CODE W/2006 REVISIONS |
| 2004 FLORIDA BUILDING CODE W/ 2006 REVISIONS |
| CITY OF WEST PALM BEACH AMENDMENTS 2004 EDITION |
| |
| STATUS: FAILED |
| |
| COMMENTS: |
| |
| 1) PLEASE PROVIDE THE DESIGN PARAMETERS AS PER THE |
| FOLLOWING: |
| |
| FLORIDA EXISTING BUILDING CODE, SECTION 407.3.1 NEW |
| STRUCTURAL FRAME MEMBERS. |
| NEW STRUCTURAL FRAME MEMBERS USED IN THE REPAIR OF |
| DAMAGED BUILDINGS, INCLUDING ANCHORAGE AND CONNECTIONS, |
| SHALL COMPLY WITH THE FLORIDA BUILDING CODE, BUILDING. |
| |
| FLORIDA BUILDING CODE |
| 1603.1.4 WIND DESIGN DATA. |
| THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL |
| BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE |
| DESIGN OF THE LATERAL-FORCE-RESISTING SYSTEM OF THE |
| BUILDING: |
| 1. BASIC WIND SPEED (3-SECOND GUST), MILES PER HOUR |
| (KM/HR). |
| 2. WIND IMPORTANCE FACTOR, IW, AND BUILDING |
| CLASSIFICATION FROM TABLE 1604.5 OR TABLE 6-1, ASCE 7 |
| AND BUILDING CLASSIFICATION IN TABLE 1-1, ASCE 7. |
| 3. WIND EXPOSURE, IF MORE THAN ONE WIND EXPOSURE IS |
| UTILIZED, THE WIND EXPOSURE AND APPLICABLE WIND |
| DIRECTION SHALL BE INDICATED. |
| 4. THE APPLICABLE ENCLOSURE CLASSIFICATIONS AND, IF |
| DESIGNING WITH ASCE 7, INTERNAL PRESSURE COEFFICIENT. |
| 5. COMPONENTS AND CLADDING. THE DESIGN WIND PRESSURES |
| IN TERMS OF PSF (KN/M2) TO BE USED FOR THE SELECTION OF |
| EXTERIOR COMPONENTS AND CLADDING MATERIALS NOT |
| SPECIFICALLY DESIGNED BY THE REGISTERED DESIGN |
| PROFESSIONAL. |
| |
| 2) PLEASE SUBMIT A FLOOR PLAN INDICATING THE NUMBER OF |
| WINDOW OPENINGS, DIMENSIONS, AND DESIGN PRESSURES. |
| |
| 3) PLEASE INDICATE WHETHER THE WOOD TRUSSES SHOWN ON |
| DETAIL #2 ARE EXISTING OR NEW. |
| |
| 4) PLEASE PROVIDE PRODUCT APPROVALS FORNEW FRAMING |
| MEMBER STRAPS AND ANCHORS AS PER THE FOLLOWING: |
| |
| 9B-72.005 SCOPE. |
| (1) PRODUCTS IN THE FOLLOWING CATEGORIES AS DEFINED BY |
| SUBCATEGORIES OF SUBSECTION 9B-72.010(31), F.A.C., |
| SHALL BE AVAILABLE FOR |
| APPROVAL BY THE COMMISSION PURSUANT TO RULE 9B-72.090, |
| F.A.C., FOR USE IN THE STATE: |
| (A) PANEL WALLS; |
| (B) EXTERIOR DOORS; |
| (C) ROOFING PRODUCTS; |
| (D) SKYLIGHTS; |
| (E) WINDOWS; |
| (F) SHUTTERS; AND |
| (G) STRUCTURAL COMPONENTS. |
| (2) THIS RULE APPLIES TO APPROVAL OF PRODUCTS AND |
| SYSTEMS, WHICH COMPRISE THE BUILDING ENVELOPE AND |
| STRUCTURAL FRAME, FOR |
| COMPLIANCE WITH THE STRUCTURAL REQUIREMENTS OF THE |
| FLORIDA BUILDING CODE. |
| SPECIFIC AUTHORITY 553.842(1) FS. LAW IMPLEMENTED |
| 553.842(5) FS. HISTORY?NEW 11-22-06. |
| |
| 5) PLEASE COMPLETE AND SUBMIT SHUTTER INSTALLATION |
| SCHEDULE FORM. |
| |
| PLAN REVIEW: KEN CONRAD |
| PHONE: 561.805.6666 |
| E-MAIL: KCONRAD @WPB.ORG |
| |
| |