2008-02-11 21:13:406316 S DIXIE HWY
 LA SIRENA RESTAURANT
 FEB. 11,2008
  
  
 BUILDING PLAN REVIEW
 PERMIT: 08010629
 ADD: 6316 S DIXIE HWY
 CONT: KARNS CONSTRUCTION
 TEL: (561)805-7528
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW
 ACTION: DENIED
  
 1A)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 1B) PLEASE SUBMIT 2 OF ALL SURVEYS, PLANS, REPORTS,
 REVISIONS , PRODUCT APPROVALS AND OR SUBMITTALS FOR
 REVIEW FOR PERMIT. IF YOUR PROJECT WILL REQUIRE A
 RESIDENT INSPECTOR OR IF YOUR PROJECT IS A THRESHOLD
 BUILDING REQUIRING A THRESHOLD INSPECTOR THEN (3) THREE
 SETS OF ALL SAID DOCUMENTS WILL BE REQUIRED FOR PERMIT
 ISSUANCE. 106.1* /2004 SUBMITTAL DOCUMENTSWEST PALM
 BEACH ADMINISTRATIVE CODE.
  
 1C) 106.1.1* W.P.B. ADMINISTRATIVE CODE/2004
 DRAWINGS & SPECIFICATIONS SHALL CONTAIN INFORMATION, IN
 THE FORM OF NOTES OR OTHERWISE, AS TO THE QUALITY OF
 MATERIALS, WHERE QUALITY IS ESSENTIAL TO CONFORMITY
 WITH THE TECHNICAL CODES. SUCH INFORMATION SHALL BE
 SPECIFIC TO THE TECHNICAL CODES "SHALL NOT BE CITED AS
 A WHOLE OR IN PART, NOR THE TERM "LEGAL" OR ITS
 EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC
 INFORMATION". CONSTRUCTION DOCUMENTS SHALL BE
 SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND
 EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT
 WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL.
  
 1D ) FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE
 WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT
 ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6)
 THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE
 CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. NOTE NOC
 SUBMITTED.
  
 1E) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW)
 AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC
 BUILDING WITH THE2007 SUPPLEMENTS PLEASE UPDATE PLANS
 TO THE 2007 FBC SUPPLEMENTS..
  
 2) PLANS DO NOT PROVIDE THE BASIC CRITERIA FOR WIND
 DESIGN. 1609.6.2 WIND DESIGN PROCEDURES
 1)THE BASIC WIND SPEED, V, SHALL BE DETERMINED IN
 ACCORDANCE WITH SECTION 1609.3.
 THE WIND SHALL BE ASSUMED TO COME FROM ANY
 HORIZONTAL DIRECTION.
  
 2) AN IMPORTANCE FACTOR, IW, SHALL BE DETERMINED
 IN ACCORDANCE WTIH SECTION1609.5.
  
 3) AN EXPOSURE CATEGORY SHALL BE DETERMINED IN
 ACCORDANCE WITH 1609.4.
  
 4) A HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENT, *
 SHALL BE DETERMINED FROM TABLE
 1609.6.2.1(4)
  
 3)PLANS DO NOT PROVIDE THE VERTICAL, HORIZONTAL OR
 GRAVITY LOADS THE TRUSSES ARE GOING TO BE SUBJECTED TO,
 PLEASE PROVIDE THESE VALUES 1609.1.3 ANCHORAGE AGAINST
 OVERTURNING, UPLIFT AND SLIDING. . 1609.1.1MAIN WIND
 FORCE RESISTING SYSTEMS.
  
 4) PLANS DO NOT PROVIDE ROOF VENTILATION AT LEAST 3
 FEET ABOVE THE EAVE VENTS, 50% OF THE REQUIRED
 VENTILATION MUST BE DERIVED FROM THESE VENTS, 1203.2
 ATTIC VENTING.
  
 5) SHEET # 2 ALTERNATE INSULATION AS STATED ABOVE IN
 COMMENT ?1C? ONLY ONE TYPE OF INSULATION CAN BE
 SPECIFIED, IF THE ICYNENE INSULATION IS THE CHOSEN THIS
 IS CONSIDERED AIR CONDITIONED SPACE AND THE EAVE AND
 UPPER THIRD ROOF VENTILATION IS NOT REQUIRED.
  
 6) SHEET # 2 INDICATES THE ROOF SHEATHING TO BE NAILED
 OFF WITH 8DX 1 ?? SPIRAL SHANK NAILS.
 THESE ARE SHORT NAILS TO BE USED IN THE NAILING OF
 STRAPS INTO TRUSSES. A 8D COMMON NAIL IS 2 ?? LONG.
 SEE THERE IS NO VALUES IN SIMPON OR USP CATALOG FOR
 NAILS THAT DO NOT HAVE A 1 ?? PENETRATION INTO THE
 FRAMING MEMBERS. PLEASE CORRECT, SEE MANUFACTURERS
 SPECIFICATION.
  
 7)PLANS DO NOT PROVIDE ATTIC ACCESS, SEE 1209.2.
  
 8) FL BLD CODE 1609.1.4: COMPONENTS & CLADDING,
 PROVIDE 2 COPIES, 3 IF THRESHOLD OR RESIDENT INSPECTOR
 OF PRODUCT TESTING REPORTS, MISSING REPORTS ARE AS
 FOLLOWS:
 8A)TRUSS ANCHOR STRAPS
 8B)PRE-ENGINEERED A/C STANDS (ROOF MOUNT)
 8C)ROOF VENTS IF THE ICYNENE INSULATION IS NOT USED
 8D) METAL ROOF PANEL- COMPLIED!
  
  
 9)PRODUCT APPROVALS SUBMITTED WITH PERMIT
 APPLICATION AFTER OCTOBER 1, 2003 ARE REQUIRED TO
 COMPLY WITH THE FLORIDA PRODUCT APPROVAL SYSTEM. FOR
 INFORMATION PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH STATEWIDE
 APPROVAL ARE REQUIRED TO BE SUBMITTED WITH A COVER
 SHEET THAT LISTS THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE STATEWIDE APPROVAL,
 SUBMIT AN APPLICATION FOR LOCAL PRODUCT APPROVAL OR
 SITE SPECIFIC FORM PER RULE 9B-72. SEE ATTACHMENT.
 WWW.FLORIDABUILDING.ORG
  
 10)WPB ADMIN CODE 106.3* PRODUCT APPROVALS. THOSE
 PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)659-8026
 E-MAIL: [email protected]
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.