Plan Review Notes For Permit 08010582 |
Permit Number |
08010582 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2008-01-31 16:52:30 | | | | | DENIED | | | | | | 1)CONSTRUCTION DOCUMENTS SHALL SHOW THE SIZE, SECTION | | AND RELATIVE LOCATIONS OF STRUCTURAL MEMBERS WITH FLOOR | | LEVELS, COLUMN CENTERS AND OFFSETS FULLY DIMENSIONED. | | THE DESIGN LOADS AND OTHER INFORMATION PERTINENT TO THE | | STRUCTURAL DESIGN REQUIRED BY SECTIONS 1603.1.1 THROUGH | | 1603.1.8 SHALL BE CLEARLY INDICATED ON THE CONSTRUCTION | | DOCUMENTS FOR PARTS OF THE BUILDING OR STRUCTURE, PER | | 1603.1 FBC.(WIND LOADS, FLOOR LOADS, | | SOIL BEARING PRESSURE AND DESIRED SOIL DENSITY FOR | | FOUNDATIONS, ETC.) | | | | 2)IN AN EXISTING BUILDING WHERE ALTERATIONS ARE BEING | | MADE A DESIGN PROFESSIONAL MUST ELECT THE LEVEL OF | | ALTERATION PER 301.5 OF EXISTING BUILDING CODE AND | | STATE ALONG WITH THE TYPE OF CONSTRUCTION ON THE | | DRAWINGS | | | | 3)MORE INFORMATION IS REQUIRED: | | A) SHOW LOCATION OF WORK IN RELATION TO ENTIRE | | BUILDING | | B) IS THEIR AN EXISTING FOUNDATION UNDER 8" CBS WALL | | AND IF SO IS THE 30"X30" PAD ATTACHED OR UNDERNEATH | | EXISTING | | C) WILL BEAM SET ON CBS WALL, IN A POCKET OR AS NOTE | | STATES ON A 4X4 COLUMN | | D) PROVIDE CORRECT ADDRESS ON DRAWINGS | | | | 4)PROVIDE PRODUCT APPROVALS FOR SIMPSON TIES. PLEASE | | NOTE THAT HGMA10 IS A WOOD TO MASONRY/CONCRETE | | APPLICATION AND YOUR JOIST TO BEAM IS AN ALL WOOD | | CONDITION | | | | BLDG PLAN REVIEW | | ADRIAN MORSE | | 561-805-6716 |
|