Notes
Date Text
2008-01-28 10:43:28PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH
 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO
 CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.), AND FLORIDA STATUTES (F.S.).
  
 PLUMBING PLAN REVIEW:
 DENIED:
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE.
  
 1. SHEET A-1 IS INDICATING THE APPLICABLE CODE WRONG
 PLEASE CORRECT THE AMENDMENTS FROM 2006 TO 2007
 REVISIONS. PER FBC PERMIT APPLICATIONS SUBMITTED AFTER
 12/8/06.
  
 2. SHEET P-1 IS INDICATING WH-1 IN THE NEW GARAGE:
 PLEASE INDICATE HOW THE WATER HEATER WILL BE PROTECTED
 FROM VEHICLE DAMAGE BY APPROVED BARRIERS. PER FBC
 MECHANICLA SECTION * 304.4.
  
 3. SHEET P-1 IS INDICATING "EXISTING SANITARY LINE TO
 BE CAPPED OFF @ EXISTING SINK". PER FBC PLUMBING
 SECTION *704.5 DEAD ENDS.
 IN THE INSTALLATION OR REMOVAL OF ANY PART OF A
 DRAINAGE SYSTEM, DEAD ENDS SHALL BE PROHIBITED.
 CLEANOUT EXTENSIONS AND APPROVED FUTURE FIXTURE
 DRAINAGE PIPING SHALL NOT BE CONSIDERED AS DEAD ENDS.
  
 4. SHEET P-1 AND P-2 INDICATE THE REQUIRED TWO-WAY
 CLEANOUTS PER FBC PLUMBING SECTION 708.3.5 BUILDING
 DRAIN AND BUILDING SEWER JUNCTION.
  
 5. SHEET P-1 PLEASE INDICATE THE LOCATION OF THE
 REQUIRED (EXISTING OR NEW), 1 AUTOMATIC CLOTHES WASHER
 CONNECTION. PER FBC PLUMBING TABLE 403.1 (R-3) ONE AND
 TWO FAMILY DWELLINGS.
  
 6. NOTE: PLEASE KNOW AS FOR INFORMATIONAL PURPOSES,
 THE POOL/SPA SCOPE OF WORK WILL BE REQUIRED TO BE UNDER
 A SEPERATE PERMIT 106.1.
  
 ********IMPORTANT INFORMATION********
 WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION
 AND REMOVE & REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
 NOTE: THERE IS ONLY ONE CORRECTED DRAWING
 IN RED INK ON THE INDICATED PLAN SHEETS BY THIS PLANS
 EXAMINER FOR REFERENCE FOR THE
 RESUBMITTAL.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 PHONE= (561) 805-6730
 FAX= (561) 805-6731
 E-MAIL= [email protected]
  
  